Stormwater Runoff Calculator
Turn a catchment and a design storm into the two numbers everything downstream needs: how much water, and how fast it arrives.
Quick answer: 2,000 sq ft with a 0.9 coefficient under 1.5 in of rain produces 1,682 gallons — 225 cubic feet. At 3 in/hr the peak flow is 56.1 gpm, and the implied storm duration is 30 minutes.
- Runoff volume in gallons and cubic feet
- Peak flow for pipe sizing
- Runoff depth and implied duration
Stormwater runoff inputs and results
Depth and intensity should describe the same storm, and the implied duration is reported so an inconsistent pair is visible.
Volume sizes storage and peak flow sizes pipework; the two figures are not interchangeable.
Show calculation
Two numbers from the same storm, and they are not interchangeable
Every drainage decision downstream of a roof depends on two numbers from the same storm: how much water arrives in total, and how fast it arrives at its peak. A storage structure is sized on the first. A pipe, gutter or channel is sized on the second.
This calculator produces both from a catchment area, a design storm depth, an intensity and a runoff coefficient. It also reports the runoff depth and the storm duration implied by the depth and intensity, which is a quick way to catch a mismatched pair of figures.

The four inputs and five results
Four fields go in. One describes the ground, two describe the storm, and one describes how much of it the surface holds back.
| Input | Unit | What it is | How to obtain it |
|---|---|---|---|
| Catchment area | sq ft | Plan area draining to the point you are designing for | Measured from the plan, not the sloped surface |
| Storm rainfall depth | in | Total depth the design event delivers | Local rainfall data for the applicable return period |
| Rainfall intensity | in/hr | The rate that depth falls at | Local intensity–duration–frequency data for the same event |
| Runoff coefficient | — | Share of rain that becomes surface flow | 0.9 for a roof; lower for lawn, gravel or a planted surface |
All four are entered on the left of the calculator, and the result updates as you type.
The five results
Three are the same volume in different forms, one is the rate, and one is a check that the storm was described consistently.
| Result | Unit | What it means |
|---|---|---|
| Runoff depth | in | Rainfall depth reduced by the coefficient — the depth that actually runs off. |
| Runoff volume | gal | Total water the catchment delivers over the event. |
| Volume in cu ft | cu ft | The same volume in the unit storage structures are measured in. |
| Peak flow | gpm | The highest rate the catchment delivers, from the rational method. |
| Implied duration | min | Depth divided by intensity — how long the storm would have to last to deliver that depth at that rate. |
The implied duration is a consistency check, not an input: if it comes out at five minutes or five hours, the depth and the intensity probably describe different storms.
One storm, described twice
The catchment is measured. The storm is looked up, and it has to be looked up twice — as a depth and as an intensity — from the same event.
The catchment
Take the plan area draining to the point you are designing for, not the whole site. A soakaway serving one downspout takes the area above that downspout; a pipe taking the whole roof takes all of it.
Use plan area rather than sloped surface, because rain falls vertically. Where the eaves are deep, the roof overhang calculation gives the extra plan area the roof covers.
The depth and the intensity
These are two views of the same design storm. The depth is what falls in total; the intensity is how hard it falls. A 1.5 in storm over 30 minutes is 3 in/hr; the same 1.5 in over three hours is 0.5 in/hr.
Volume depends on the depth alone. Peak flow depends on the intensity alone. That is why the pair has to be consistent — mixing a depth from one event with an intensity from another produces two numbers that do not describe the same rainfall.
The implied duration the calculator reports is the check on that. If it does not match the duration the local data assumes, one of the two figures is from the wrong storm.
The coefficient
The coefficient is the share of rain that becomes surface flow. A roof sheds almost everything, so it sits near 0.9 or higher; a lawn holds a meaningful share back; gravel and planting hold more.
Where the catchment mixes surfaces, calculate each one separately and add the volumes. The calculator takes a single coefficient because it models a single surface.
Common measuring mistakes
- Sloped area used as catchment. It overstates both the volume and the peak flow.
- Depth and intensity from different storms. The implied duration is what exposes it.
- One coefficient for a mixed catchment. A roof draining across a lawn is two surfaces, not one.
- Whole site used for one outlet. Only the area draining to that point counts.
- Design storm chosen by habit. The return period is a risk decision set by local rules or by you.
How to use the Stormwater Runoff Calculator
You need one design storm, described twice: as a depth and as an intensity.
- Enter the catchment. Give the area draining to the point you are designing for, not the whole site.
- Describe the storm. Enter the rainfall depth for the design event and the intensity it falls at.
- Set the coefficient. Enter the share of rain that becomes surface flow for the surface you have.
- Read both outputs. Take the volume to a storage calculation, or the peak flow to a pipe or channel calculation — not the other way round.
The implied duration is worth a glance before you use either figure. It costs nothing to check and it catches the most common input error on this page.
How the volume and the peak flow are worked out
volume (gal) = area × rainfall depth × 0.623 × coefficient
volume (cu ft) = volume (gal) ÷ 7.4805
peak flow (gpm) = coefficient × intensity × area × 0.01039
implied duration (min) = rainfall depth ÷ intensity × 60
Variables
- A
- Catchment plan area, in square feet.
- D
- Storm rainfall depth for the design event, in inches.
- I
- Rainfall intensity for the same event, in inches per hour.
- C
- Runoff coefficient, dimensionless.
Unit explanation
The 0.623 converts rainfall depth over an area to gallons: one inch on one square foot is one twelfth of a cubic foot, which is 0.623 US gallons. The 7.4805 is the number of gallons in a cubic foot, so dividing by it returns the volume to the unit storage is measured in.
The peak flow line uses 0.01039, which does the same job in the other direction: one inch per hour over one square foot is 0.01039 gallons per minute. Both constants are arithmetic, and they differ because one converts a total depth and the other converts a rate.
Why two constants
The two constants look interchangeable and are not. The volume constant turns a depth into a total volume; the flow constant turns a rate into a rate. Using the wrong one gives an answer out by a factor of the storm duration.
That is also why the page asks for the storm twice. There is no way to derive the peak flow from the depth without knowing how long the storm lasted, and no way to derive the volume from the intensity without the same information.
Why the implied duration is reported
Dividing the depth by the intensity gives the duration the pair implies. It is not an input because the calculator does not need it — but it is the cheapest possible check that the two figures came from the same storm.
A 1.5 in depth at 3 in/hr implies 30 minutes, which is a normal short design storm. The same depth at 0.1 in/hr implies 15 hours, which is a different kind of event entirely and probably a mismatched pair.
Numerical example
3,500 sq ft at 2 in of rain falling at 4 in/hr, with a coefficient of 0.85:
- Runoff depth
- 2 × 0.85 = 1.70 in
- Volume
- 3,500 × 2 × 0.623 × 0.85 = 3,707 gal
- In cubic feet
- 3,707 ÷ 7.4805 = 495.5 cu ft
- Peak flow
- 0.85 × 4 × 3,500 × 0.01039 = 123.6 gpm
- Implied duration
- 2 ÷ 4 × 60 = 30 min
A 30-minute storm is consistent, so the pair can be trusted. The volume would fill a soakaway of about 500 cu ft; the peak flow is what a pipe from the roof would have to carry.
Result interpretation
The volume answers "how much storage", and the peak flow answers "how big a pipe". Neither substitutes for the other, and a system sized on the wrong one is either oversized or quietly inadequate.
The runoff depth is the least used of the five, but it is the one that explains the others: it is the rainfall after the surface has taken its share, and multiplying it by the area is the whole of the volume calculation.
Volume or peak flow — which one do you need?
The distinction matters because using the wrong one produces a system that is either far too big or quietly inadequate.
| You are sizing | Use | Because |
|---|---|---|
| A soakaway or dry well | Volume | It has to hold the water until it infiltrates. |
| A rain garden or basin | Volume | Surface area comes from the stored volume and ponding depth. |
| A rainwater tank | Volume | Storage is a volume question, not a flow question. |
| A gutter or downspout | Peak flow | The channel has to carry the highest rate, not the total. |
| A pipe or culvert | Peak flow | Capacity is a rate. |
| A swale or open channel | Peak flow | Capacity is a rate, and velocity matters too. |
| A flow-control orifice | Peak flow | The restrictor is set by the permitted discharge rate. |
Worked examples: the same depth falling harder
Example 1 — 2,000 sq ft under 1.5 in at 3 in/hr
- Runoff depth
- 1.5 × 0.9 = 1.35 in
- Volume
- 2,000 × 1.5 × 0.623 × 0.9 = 1,682 gal
- In cubic feet
- 1,682 ÷ 7.4805 = 224.9 cu ft
- Peak flow
- 0.9 × 3 × 2,000 × 0.01039 = 56.1 gpm
- Implied duration
- 1.5 ÷ 3 × 60 = 30 min
Example 2 — the same depth falling harder
- Intensity
- raised to 6 in/hr
- Volume
- unchanged at 1,682 gal
- Peak flow
- 0.9 × 6 × 2,000 × 0.01039 = 112.2 gpm
- Implied duration
- 1.5 ÷ 6 × 60 = 15 min
The same total water, arriving in half the time. A pipe sized on the first example would be carrying double its design flow in the second — which is exactly why the intensity has to match the storm you are designing for, not just the depth.
Where the two numbers go next
This page stops at a volume and a rate. Both are inputs to something else, and the handover is where the wrong figure gets used.
The roof side
The peak flow is what the gutter has to carry, and the run that delivers it is sized by gutter capacity. A gutter that passes less than this figure backs up whatever the storage downstream can take.
Where the flow leaves the roof through outlets rather than a gutter, the downspout calculation turns the same peak into a count and a spacing.
The connection
Between the downspout and wherever the water ends up there is usually a run of pipe. The gutter extension calculation sizes that distance and its fittings, and it is the part most often left as a guess.
The ground side
The volume is what a storage structure has to hold, and where the ground will not take it fast enough a trench is the answer — the french drain calculation sizes the run for the volume arriving.
A pit and a planted basin are the other two options, and the dry well and rain garden calculations on the related list size those from the same volume.

What the figures do not do
Neither number describes water quality, and neither says anything about where the water is allowed to go. Both of those come from local rules, and both can rule out a design that the arithmetic supports.
Limitations and assumptions
What the calculation assumes
- One surface, one coefficient. Mixed catchments need each surface calculated separately and the volumes added.
- A plan area catchment. The area entered is assumed to be the horizontal projection.
- Steady-state peak. The rational method ignores the time for the whole catchment to start contributing.
- A consistent storm. The depth and the intensity are assumed to describe the same event, which the implied duration checks but cannot enforce.
- No routing. Travel time along a pipe or channel is not modelled.
What it does not include
- Snowmelt. This is a rainfall model.
- Water quality. Runoff volume says nothing about what is in the water.
- The design storm choice. The return period is a risk decision set by local rules or by you.
- Infiltration or attenuation. How fast the ground or a structure releases the water is a separate calculation.
- Cost or construction. Neither number prices or details anything.
The result is the volume and the peak flow one design storm produces from one catchment. It is the input to a drainage design, not the design itself.
Frequently asked questions
Because they answer different questions. Volume decides how much storage or infiltration you need; peak flow decides how big the pipe or channel has to be. A soakaway is sized on volume. A gutter, drain or swale is sized on peak flow. Using one for the other is the most common mistake in small drainage design.
It is the share of rainfall that becomes surface flow rather than being absorbed, held or evaporated. A paved or metal surface sheds nearly all of it; grass or a planted roof holds a meaningful proportion back. It is an input because the right value depends on the surface, and published tables differ in how they treat partial absorption.
It is the rainfall event you are designing for: a depth and an intensity that go together. A larger storm means a bigger, more expensive system, so the choice is a risk decision rather than a hydraulic one. Local drainage requirements usually specify the design storm for a given application. Where they do not, the choice is yours and should be stated.
Because depth and intensity are not independent. A 1.5 in storm falling at 3 in per hour lasts about 30 minutes, and the arithmetic says so. Showing it makes an inconsistent pair obvious — if the duration comes out at three minutes or six hours, one of the two figures is wrong for the storm you have in mind.
No, and it is higher. The rational method assumes the whole catchment is contributing at the design intensity, which is a peak condition rather than an average over the storm. That is deliberate for pipe sizing, where the peak is what causes the failure.
Because different trades use different units. Storage tanks and water butts are sold in gallons or litres; soakaways and excavations are measured in cubic feet or cubic yards. Both are given so the figure can go straight into whichever calculation follows.
No. The rational method is a rainfall model. Snowmelt produces a slower, longer release that behaves differently and needs a different approach. In cold climates, design for the rainfall event and treat snowmelt as a separate check.
Calculate each surface separately with its own coefficient and add the results, or use an area-weighted coefficient. A driveway, a roof and a lawn all shed differently, and averaging them into one number hides that.
Those take the volume this page produces and turn it into a storage structure. The dry well calculator solves for pit depth.
The rain garden calculator solves for surface area instead. This page is the common first step for both.
No. It is a flow and a volume for a stated storm. Whether a downstream system can accept them, and whether the discharge point is permitted, are separate questions. Where runoff leaves the site, local rules usually govern the permitted rate and quality.
Where these numbers come from
The volume calculation is area multiplied by depth and a unit constant. The peak flow is the rational method, which is the standard approach for small-catchment drainage design and is the basis of most local roof-drainage rules.
Runoff coefficients, the design storm and the intensity are inputs. Published tables of coefficients vary in how they treat partial absorption, which is why the value is not asserted here.
- The rational method and the design storm. FAA Advisory Circular 150/5320-5C, drainage chapters (PDF, 667 KB) sets out the Rational Method, the runoff coefficient, and the use of an intensity–duration–frequency curve with the duration set by the time of concentration — which is why this page asks for the storm as both a depth and an intensity.
- Local rainfall intensity–duration–frequency data, which is the proper source for both the depth and the intensity. For sites in the United States, NOAA's Precipitation Frequency Data Server publishes those estimates.
- Local drainage or building requirements, which usually specify a design storm and may specify permitted methods.
- Published runoff coefficient tables for the surface types involved.
Need somewhere for that volume to go?