Barrel Vault Roof Calculator

Work out the curved area, developed width, radius and end wall area of a barrel vault or Quonset roof from the span, rise and length.

Quick answer: a 24 ft span vault with a 12 ft rise and a 40 ft length is a semicircle. Its developed width is 37.70 ft, giving 1,508.0 sq ft of curved surface, with 452.4 sq ft of end wall.

  • Segmental or semicircular arch
  • Developed width for flat material
  • End wall area reported separately

Barrel vault inputs and results

Rise is measured from the springing line up to the crown, not along the curve.

Span and risespanrise
The span runs across the base, the rise is the height at the centre. → curved roof area
Curved roof area
1,508.0 sq ft
37.70 ft developed × 40.0 ft · 15.08 squares · 1,658.8 with waste
Developed width
37.70 ft
Radius
12.00 ft
Rise
12.00 ft
End walls
452.4 sq ft

End walls are the circular segments above the springing line, not the full end elevation.

Show calculation

What this calculator works out

A barrel vault is a single continuous curve across the span, like half a cylinder. There is no ridge and no hip, so there is nothing to add up in planes — the whole roof is one surface.

The number that makes the calculation possible is the developed width: the arc length across the span, as though the curve were unrolled into a flat sheet. Multiply that by the length and you have the area.

That is where a vault departs from every other roof on this site. A pitched roof is a set of flat planes, so its area comes from the footprint multiplied by a pitch factor — which is what the roof area calculator does. A curve has no pitch factor, because it has no planes and no constant slope. The area has to come from the arc itself.

A barrel vault roof on a building, with a single continuous curve running from one eave to the other and corrugated cladding following the arch.
One curve, one surface. The area is the developed width multiplied by the length.

The four inputs and the seven results

Three of the four inputs come off a tape measure. The fourth is a product decision, and it is the only one you should take from the manufacturer rather than the building.

InputUnitWhat it isHow to obtain it
SpanftThe straight-line width across the mouth of the arch, eave to eaveMeasure across the opening, not over the curve
RiseftThe height from the springing line to the crownMeasure vertically. Half the span is a semicircle; more than half is rejected
LengthftThe straight run of the vaultMeasure along one eave, excluding the end walls
Waste%Allowance for laps and the curved cuts at each endThe cladding manufacturer's figure for the profile and the radius

No unit conversion: enter every dimension in feet. The span is capped at 200 ft, the length at 500 ft and the waste at 40%, and a rise above half the span is refused rather than calculated.

ResultUnitWhat it means
Curved roof areasq ftDeveloped width × length. The surface you are covering
Developed widthftThe arc across the span unrolled into a flat dimension — the number you order flat material against
RadiusftThe radius of the circle that fits the span and the rise, derived rather than measured
RiseftThe rise used in the calculation, echoed back so you can confirm the input was read as intended
End wallssq ftBoth end walls: two circular segments above the springing line, not the full end elevation
SquaressquaresCurved area ÷ 100, for comparing with a roofing quote
Area with wastesq ftCurved area × (1 + waste). What to order, before laps are applied per sheet

The end walls are reported apart from the roof area on purpose. On a Quonset they are the same profile as the roof; on a building they are usually a wall in another material. Adding them into the roof figure would over-order the covering.

How to Use the Barrel Vault Roof Calculator

There is no calculate button. The curved area, the developed width, the radius and the end wall area all update as you type, so the quickest way to use this page is to enter the three dimensions and then vary the rise to see how much the curve is costing you.

  1. Measure the span. The straight-line distance from one eave to the other, across the mouth of the arch — not the distance over the curve.
  2. Measure the rise. The height from the springing line to the crown. If the rise equals half the span you have a semicircle; anything less is a segmental arch.
  3. Measure the length. The straight run of the vault. Exclude the end walls, which are calculated separately.
  4. Set the waste allowance. This covers sheet laps and the curved cuts at each end. Take it from the cladding manufacturer's figure rather than a general rule.
  5. Read the curved area first, then the developed width. The area is what you need for quantity; the developed width is what you order material against.
  6. Check the end walls as a separate number. They are a different material and a different trade, and mixing them into the roof area inflates the order.

If you are measuring an existing arch, the rise is far easier to take than the radius. The calculator derives the radius from the span and the rise, which is why you never need to find the centre of the circle.

A rise above half the span is rejected rather than calculated. That is deliberate: past that point the roof uses more than a half circle, and the arithmetic behind this page would quietly return the shorter arc instead.

The formulas

radius = (span² ÷ 4 + rise²) ÷ (2 × rise)
half angle = arcsin( (span ÷ 2) ÷ radius )
developed width = 2 × radius × half angle
curved area = developed width × length
end walls = 2 × radius² × (half angle − sin × cos)

Radius from the span and the rise

Formula. Radius = (span² ÷ 4 + rise²) ÷ (2 × rise).

Variables. Span and rise in feet. The radius comes out in feet, and the half angle in radians — not degrees — because every line below uses it in radian form.

Why it is calculated this way. This is the circle through three points: the two springing points and the crown. Given a chord and a sagitta — which is what the span and the rise are — there is exactly one circle that passes through all three, so the radius is determined by the two measurements you can actually take.

Example. A 24 ft span with a 12 ft rise: (576 ÷ 4 + 144) ÷ (2 × 12) = 288 ÷ 24 = 12.00 ft.

Reading the result. A radius equal to half the span means the rise is half the span, so the arch is a semicircle. A radius larger than half the span means a shallower segmental arch.

Developed width

Formula. Half angle = arcsin((span ÷ 2) ÷ radius). Developed width = 2 × radius × half angle.

Variables. The half angle is in radians. Multiplying it by the radius twice over gives the full arc length, because arc length is radius × angle for the whole subtended angle, which is twice the half angle.

Why it is calculated this way. The developed width is the arc unrolled into a straight dimension. It is not the span, and that is the single most common mistake on a curved roof: a semicircular vault with a 24 ft span develops to 37.70 ft, not 24 ft. Using the span under-orders the covering by more than a third.

Example. Semicircle: arcsin(12 ÷ 12) = 90° = 1.5708 rad, so the width is 2 × 12 × 1.5708 = 37.70 ft. For a semicircle this collapses to π times the radius, which is the familiar result.

Reading the result. This is the dimension flat material is ordered against, and it is also the distance a sheet has to bend over the arch — which is why it has to be checked against the profile's minimum radius.

Curved area and end walls

Formula. Curved area = developed width × length. End walls = 2 × radius² × (half angle − sin × cos).

Variables. Length in feet, radius in feet, half angle in radians. The area comes out in square feet, the end walls in square feet for both ends combined.

Why it is calculated this way. The area is a rectangle once the curve is developed, so it is a single multiplication. The end wall formula is the area of a circular segment: the sector minus the triangle bounded by the chord and the two radii. It is the shape above the springing line, not the whole end elevation.

Example. 37.70 × 40 = 1,508.0 sq ft of curved surface. End walls: 2 × 144 × (1.5708 − 1 × 0) = 452.4 sq ft, because at 90° the sine is 1 and the cosine is 0.

Reading the result. The end walls are a separate quantity for a reason — they are usually a different material — so they are reported apart from the roof area rather than added to it.

Segmental or semicircular

The rise decides which you have, and it changes the answer more than you might expect.

Rise equal to half the span is a semicircle. The springing points are level with the centre of the circle, and the arch is at its deepest for that span.

Rise less than half the span is a segmental arch. The circle is larger and its centre sits below the springing line, so the arc is shallower and the developed width is shorter.

The effect is significant. On a 24 ft span, dropping the rise from 12 ft to 6 ft takes the developed width from 37.70 ft to 27.82 ft and the area from 1,508 to 1,113 sq ft on the same 40 ft length — a 26% reduction from halving the rise.

Rise on a 24 ft spanFormRadiusHalf angleDeveloped widthCurved area, 40 ft long
6 ftSegmental15.00 ft53.13°27.82 ft1,113 sq ft
12 ftSemicircle12.00 ft90°37.70 ft1,508 sq ft
18 ftHorseshoe13.00 ft112.62°51.11 ft on the major arcNot modelled

Every figure in the first two rows is this calculator's output. The third row is shown to explain the limit, not as a supported calculation.

A rise above half the span is a horseshoe arch. The springing points sit inside the circle, so the roof uses more than a semicircle and the arc is the major one.

That matters because the formula on this page would not fail loudly. The arc sine returns an angle between zero and 90° — it can describe the minor arc and nothing else — so on an 18 ft rise it would hand back 67.38° and a developed width of 30.58 ft, when the real figure on the major arc is 112.62° and 51.11 ft. The calculator refuses the input instead of printing a number that is out by 40%.

If your rise is more than half the span, stop. You are looking at a horseshoe or Moorish arch, which is a different form with a different calculation. Nothing on this page applies to it.
The curved profile of a barrel vault roof seen end on, showing the arch springing from the walls and rising to a crown.
The rise is measured from the springing line to the crown. It is the easiest dimension to take on an existing arch.

Worked examples

Example 1 — 24 ft span, 12 ft rise, 40 ft long

Radius
(576 ÷ 4 + 144) ÷ 24 = 12.00 ft
Half angle
arcsin(12 ÷ 12) = 90°
Developed width
2 × 12 × 1.5708 = 37.70 ft
Curved area
37.70 × 40 = 1,508.0 sq ft
Squares
1,508.0 ÷ 100 = 15.08
End walls
2 × 144 × 1.5708 = 452.4 sq ft

The rise equals half the span, so this is a semicircle and the developed width is exactly π times the radius — 3.14 times half the span, not the span itself.

area = 37.70 × 40 = 1,508.0 sq ft

Example 2 — a shallower segmental arch

Roof
20 ft span, 6 ft rise, 30 ft long
Radius
(400 ÷ 4 + 36) ÷ 12 = 11.33 ft
Half angle
arcsin(10 ÷ 11.33) = 61.93°
Developed width
2 × 11.33 × 1.0808 = 24.50 ft
Curved area
24.50 × 30 = 735.0 sq ft
End walls
2 × 128.4 × (1.0808 − 0.882 × 0.471) = 171.0 sq ft

The radius is larger than half the span here, which is what makes the arch shallow: the circle's centre sits below the springing line and the arc is a small part of it.

area = 24.50 × 30 = 735.0 sq ft

Limitations and assumptions

  • Circular arc. An elliptical or parabolic vault has a different developed width.
  • Rise no more than half the span. A horseshoe arch is a different form.
  • Constant radius along the length. A tapering or conical vault is not modelled.
  • No sheet laps. The developed width is the geometric arc; laps go in the waste allowance.
  • End walls are segments only. A wall below the springing line is a separate takeoff.
  • No framing or shell design. The structural behaviour of a vault is not arithmetic.

When this is the wrong shape

If the roof is two flat planes meeting along a ridge, nothing on this page applies. The steep symmetric case is an A-frame; the asymmetric one, where the planes fall at different pitches, is a saltbox.

If the planes meet at a point rather than a line, the form is a pyramid or a cone, and the arithmetic there works from the base rather than from an arc.

The distinction is worth making before you measure anything, because the inputs are not transferable. A vault takes span, rise and length; a pyramid takes base width, height and the number of sides. Entering a vault dimension into a plane-based tool produces a number, but it is not the number you need.

Frequently asked questions

A roof formed by a single continuous curve from one eave to the other, like the top half of a cylinder laid on its side. The curve is circular, so the roof has one radius and no ridge, hip or valley. It is also called an arched roof or a vaulted roof. The curved surface is a single plane in the sense that it has no joints in the direction of the span.

Geometrically, yes. A Quonset hut is a semicircular barrel vault built from corrugated steel, springing from ground level or from a low kerb. The name describes the construction rather than the shape, which is why both terms lead to the same calculation.

Because not every barrel vault is a semicircle. A segmental vault uses an arc shorter than a half circle, which makes the roof shallower for the same span and gives a smaller area. Enter the rise as half the span for a true semicircle, or less for a segmental arch. The calculator derives the radius from the two.

By developing the curve into a flat width. The arc length across the span is the width of the material if you could unroll it, and the area is that width multiplied by the length. For a semicircle the arc length is π times the radius, which is about 3.14 times half the span — noticeably more than the span itself.

It is the width of a sheet or a membrane if it were laid flat, so it is the number you order against for any material supplied in flat widths. It is also the distance a sheet has to span when it is bent over the arch, which matters for the maximum radius a given profile can take.

Yes, if the covering is corrugated or profiled. Sheets lap along their length, and the lap depends on the profile and on the pitch of the curve. That is what the waste allowance is for here. Set it from the cladding manufacturer's figure rather than a general rule.

No. The length is the straight run of the vault, and the curved area is that length multiplied by the developed width. The end walls are separate: each is a circular segment, and their combined area is reported as a tile because they are a different material and a different trade.

Closing the ends of the vault. On a Quonset they are usually the same profile as the roof, cut to the segment shape; on a building they are often a gable wall in another material. The area reported is the segment above the springing line, not the whole end elevation.

That would be a horseshoe arch, where the curve continues past vertical. It is a real form but it is not a barrel vault in the usual sense, and this calculator rejects it. Half the span gives a semicircle, which is the deepest ordinary case.

More than on a flat roof, because curved sheets are cut on a curve at the ends and the offcuts are not reusable. The allowance is a product decision and the manufacturer publishes a figure. It is an input here rather than a built-in number.

Where these numbers come from

The radius comes from the chord-and-sagitta relationship for a circular arc, which is the same construction used to find the centre of any arc from three points. The developed width is the arc length, and the area is that length times the run.

The end wall area is a circular segment: the sector area minus the triangle bounded by the chord and the two radii. Both are standard results and neither depends on a table.

Nothing here is quoted from a published table, and that is deliberate rather than an omission. A circular arc is fully determined by two measurements, so the geometry can be checked by hand — the worked examples on this page show every step. The only genuinely product-specific figures are the minimum bend radius and the lap allowance, and those differ between profiles and manufacturers, which is why they are inputs rather than constants.

  • Your own measurement of span, rise and length.
  • The cladding manufacturer's minimum radius for the profile, and their lap figures. These are published per product and are not transferable between systems.
  • A structural engineer for the shell, which carries load very differently from a framed roof.

Curved in two directions?

A dome is a spherical surface, which has its own formula and no developed width.

Scroll to Top