Solar Roof Savings Calculator
Convert a system size into annual production, bill savings, the share of your consumption it covers, and a simple payback figure.
Quick answer: a 6 kW system at 4.5 peak sun hours and a 0.8 performance ratio produces 7,884 kWh a year. At $0.15 per kWh that is about $1,183 saved, and a $15,000 system pays back in roughly 12.7 years.
- Annual kWh and savings
- Bill offset
- Simple payback
Solar roof savings calculator inputs and results
Enter zero consumption if you only want production and savings.
One rate applied to all production assumes self-consumption; export tariffs, financing and inverter replacement are not modelled.
Show calculation
What this calculator works out
The short version: a 6 kW array at 4.5 peak sun hours and a performance ratio of 0.8 makes 7,884 kWh a year. At $0.15 a kilowatt-hour that is $1,182.60 saved annually, a 98.6% bill offset against 8,000 kWh of consumption, and a 12.7-year payback on a $15,000 installation.
Production is physics; savings are arithmetic on top of it. This calculator takes a system size and converts it into annual energy, then prices that energy at a rate you supply, and compares it with your consumption and the installed cost.
The distinction matters because a system can be well designed and still save little, if production lands mostly in hours when the house is not using power.
The system size itself comes from the roof rather than from this page: the solar roof calculator turns usable roof area into panel count and kilowatts, and that figure is what gets priced here. And a roof has other possible jobs — a growing system is one of them, which the green roof calculator weighs against the structure it sits on.

What you enter, and what comes back
Six inputs, and one of them decides most of the answer.
| Input | What it means | Where it comes from |
|---|---|---|
| System size | Array capacity in kilowatts | From roof area and layout — the solar panel area calculator works out how many modules fit |
| Peak sun hours | Equivalent full-sun hours per day at the site | A solar resource dataset |
| Performance ratio | Share of theoretical output surviving real conditions | 0.75 to 0.85 typically |
| Electricity rate | What a kilowatt-hour is worth — imported or exported | Your bill, or a published average |
| Installed cost | Total price of the system, before incentives | The quote |
| Annual consumption | Kilowatt-hours the property uses in a year | Twelve months of bills |
| Result | Unit | How to use it |
|---|---|---|
| Annual production | kWh | Size × sun hours × performance ratio × 365. |
| Annual saving | $ | Production × rate. Every dollar figure below follows from this one. |
| Bill offset | % | Production ÷ consumption. Above 100% the surplus is not worth the same as the rest. |
| Simple payback | years | Installed cost ÷ annual saving. Undiscounted, and before any tariff change. |
| 25-year savings | $ | Annual saving × 25, with no degradation, no tariff rise and no inverter replacement. |
The 25-year figure is the one most often quoted and the least reliable: it assumes the first year repeats unchanged twenty-five times, which no tariff and no module does.
How to use the solar roof savings calculator
Production, bill offset and payback from your own tariff and installed cost.
- Enter the system. Give the system size and the annual yield per kW for the location.
- Enter the tariff. Give the electricity rate you pay.
- Enter the cost. Give the installed cost of the system.
- Read the payback. The result gives annual production, bill offset and simple payback in years.
The formulas
annual saving = annual kWh × rate
bill offset = annual kWh ÷ consumption × 100
simple payback = installed cost ÷ annual saving
Simple payback is deliberately simple. It answers "how many years of savings equal the cost" and nothing more; it does not discount future cash or assume a tariff increase.
Worked examples
Example 1 — a 6 kW system at $0.15 per kWh
- Annual production
- 6 × 4.5 × 0.8 × 365 = 7,884 kWh
- Annual saving
- 7,884 × $0.15 = $1,182.60
- Bill offset
- 7,884 ÷ 8,000 = 98.6%
- Payback
- $15,000 ÷ $1,182.60 = 12.7 years
Example 2 — the same system on a low export rate
- Effective rate
- $0.06 per kWh exported
- Annual saving
- 7,884 × $0.06 = $473.04
- Payback
- $15,000 ÷ $473.04 = 31.7 years
The same hardware, a very different outcome. What a kilowatt-hour is worth is the single most important input on this page.
What a kilowatt-hour is worth
Everything on this page is a rate multiplied by a quantity. The quantity is fixed by the hardware and the weather; the rate is a commercial arrangement, and it moves the answer further than any physical variable does. Holding production at 7,884 kWh and the installed cost at $15,000:
| Value per kWh | Annual saving | Simple payback |
|---|---|---|
| $0.06 — exported, low tariff | $473 | 31.7 years |
| $0.10 — part self-used, part exported | $788 | 19.0 years |
| $0.15 — imported retail rate | $1,183 | 12.7 years |
| $0.25 — high retail rate | $1,971 | 7.6 years |
A fourfold difference in rate turns a 32-year payback into a 7.6-year one, on identical hardware. That is why a savings estimate is only as good as the tariff it assumes — and why two neighbours with the same roof can get very different answers.
Why the single-rate model overstates an oversized array
The calculator prices every kilowatt-hour at one rate. In practice the first ones are worth the retail rate because they replace power you would have bought, and everything beyond your consumption is worth only the export rate, which is usually much lower.
Take the same array against 5,000 kWh of consumption rather than 8,000. The first 5,000 kWh save 5,000 × $0.15 = $750. The remaining 2,884 kWh are exported at $0.06, worth $173. The real saving is $923, not the $1,183 the single-rate figure gives — a 28% overstatement, and a payback of 16.3 years rather than 12.7.
None of that makes the array a bad purchase. It means the size should be matched to consumption, or to a tariff that pays properly for export, and that the last few panels are worth less than the first.
Limitations and assumptions
- One rate for everything. Self-consumption and export are not separated.
- No tariff escalation. Future price rises would shorten payback.
- No financing. Interest and fees are excluded from the cost.
- No degradation or replacement. Inverter replacement and module degradation are ignored.
- No tax or incentive treatment. Rebates and tax credits change the effective cost.
- No structural content. What the array weighs is a separate takeoff, what it adds to the roof is the roof weight calculator's, and whether the roof can carry it is an engineer's.
- Not solar shingles. A roof-integrated system replaces the covering rather than sitting above it, so its cost and its production are counted differently — that is the solar shingle calculator.
- No allowance for a roof that needs work first. If the covering is near the end of its life, the array will have to come off and go back on, which changes the payback more than a tariff does. Re-covering with an array in view is a planning question in its own right.

Frequently asked questions
Multiply annual production by your electricity rate. A 6 kW system producing 7,884 kWh at $0.15 per kWh saves about $1,183 a year, before any export tariff or time-of-use effect. Production depends on location and system design, and the rate depends on your tariff, so both are inputs here rather than fixed values.
It is the installed cost divided by annual savings, giving the number of years before the system has paid for itself in cash terms. It ignores electricity price inflation, financing interest, inverter replacement and the time value of money, so it is a rough comparison tool rather than a financial model.
Because production can exceed consumption. Without a battery or an export agreement, surplus generation may be exported at a lower rate or curtailed, so the saving is not simply production times the retail rate. If the offset figure is above 100%, treat the savings estimate as an upper bound.
No. It applies one rate to all production, which assumes self-consumption at the retail rate. Export tariffs, net metering and time-of-use pricing all change the arithmetic. For an accurate figure, split self-consumed and exported energy and apply the correct rate to each.
Use the rate you actually avoid paying. If you self-consume, that is the retail rate including taxes and levies. If you export, it is the export rate, which is usually much lower. Blending the two into one number is the most common source of over-optimistic savings estimates.
Modules lose output slowly over their life, typically a fraction of a percent a year. This calculator uses a single first-year production figure and does not model degradation. Over a 25-year horizon the cumulative effect is real but modest compared with variations in tariff and consumption.
It can. Cleaning, occasional repairs and an inverter replacement at some point in the system's life are real costs that simple payback ignores. Adding those to the installed cost gives a more realistic figure.
Not necessarily. A cheaper system with a shorter payback may produce less energy over its life, or use equipment with a shorter warranty. Payback is one measure; levelised cost and lifetime yield are others, and they can rank options differently.
The arithmetic is the same, but commercial tariffs, demand charges and different export arrangements change what a kilowatt-hour is worth. Model those separately rather than entering a single blended rate.
Where these numbers come from
Production uses the standard energy identity: capacity times equivalent full-sun hours times a loss factor. Savings are that energy multiplied by a tariff.
Both empirical inputs — sun hours and rate — are yours to supply, because neither is a constant.
- Local irradiance datasets for peak sun hours.
- Your electricity tariff, including taxes and levies, for the avoided cost.
- Installer quotations for installed cost, and any incentive documentation for the net cost.
- U.S. Energy Information Administration, Electric Power Monthly — Chapter 5 publishes sales, revenue and average price of electricity by state and sector, which is the public benchmark for the rate input. Use your own tariff for the calculation; use this to check whether it is plausible.
This page is arithmetic on your inputs. It is not financial advice.
Not sure what system size you can fit?