Collar Tie Calculator
Work out the length of a collar tie at a chosen height above the wall plate, how many the roof needs, and the total footage.
Quick answer: a 30 ft span at 6:12 with the tie 4 ft above the plate is 14.00 ft long, against a ridge rise of 7.50 ft. At 4 ft centres along a 40 ft building that is 11 ties and 154.0 ft of timber.
- Length from span, pitch and heig
- Count from the length and spacing
- Total linear feet
Collar tie inputs and results
Height above plate is measured up the rafter line, so at the ridge the tie length falls to nothing.
Ties are counted along the ridge at your spacing, and the total is that count multiplied by one tie length.
Show calculation
What this collar tie calculator works out
A collar tie is a horizontal member joining a pair of opposing rafters somewhere in the upper part of the roof. The higher it sits, the shorter it gets, and the less work it does.
Give the page a span, a pitch, a height and a spacing, and it returns the length of one tie at that height, how many run along the building, and the total footage. It also reports the ridge rise, so you can see straight away whether the height you asked for is even inside the roof.
It does not choose the height, size the member, or design the connection. Those are the three questions that decide whether a collar tie is doing anything useful, and none of t
The tie spans between two rafters, so its length depends on where those rafters are. The rafter length calculator fixes the rafter line from the run, pitch and overhang. Five inputs, five results. The first three set the length of one tie; the last two set how many you need. Lengths are shown to two decimal places and the count is a whole number, rounded down from the division so that ties are not crowded closer than the spacing you asked for. Five inputs. The first three set the length of one tie; the last two set how many you need. The results update as you type. Before you accept the result, do one check the calculator cannot do for you. Multiply the ridge rise by two-thirds to find the bottom of the upper third, and confirm your tie height is above it. On a 30 ft span at 6:12 the ridge rise is 7.50 ft, so a compliant tie sits at 5.00 ft or higher. If your height comes out below that line, you are specifying a rafter tie, not a collar tie, and the sizing question changes. Open Show calculation to see each step, and use Copy results to move the length, count and total into a cut list. Reset restores the defaults. The travel is how far horizontally each rafter has moved inward by the time it reaches the tie height. Twice that, subtracted from the span, is the gap between them. The ridge rise uses half the span, which is the run. Rafters converge at a fixed rate: for every 12 in of horizontal run they rise by the pitch. Turned around, that means for every 12 in the tie rises, each rafter has moved 12 ÷ pitch inches inward. The tie loses twice that, once from each side. On a 6:12 roof the pitch ratio is 0.5, so each foot of height moves each rafter 2 ft inward and shortens the tie by 4 ft. That is a fast rate. A tie that is 26 ft long at 1 ft above the plate is 2 ft long at 7 ft, on the same roof. The height is capped by the ridge. Once the tie reaches the ridge rise there is no gap left to span, so the useful range runs from the plate up to the ridge and no further. You can get that figure from the roof height estimator if you have not worked out the rise yet. This is the table that surprises people. A collar tie placed where the code expects it, in the upper third, is a short member — between 2 ft and 10 ft on this roof. That is not a mistake in the arithmetic. It is the reason a collar tie is not the same thing as a rafter tie. Most of the advice online gets this backwards, so it is worth stating plainly. A collar tie sits in the upper third of the roof and connects opposing rafters. A rafter tie — usually the ceiling joist — sits at plate level and does the heavy work of resisting outward thrust. Both resist the roof trying to spread, but not equally. Thrust acts at the plate, so a member at plate level acts directly against it. Raise the member and it works through a shorter lever, while the rafter below it can still bow outward. A collar tie therefore helps, but it is not a substitute for a rafter tie, and it was never intended to be one. What the code actually asks for is modest and specific. IRC R802.4.6 states that where collar ties are used to connect opposing rafters, they shall be: The same section allows ridge straps to replace collar ties: not less than 1¼ in by 20 gauge, nailed to the top edge of each rafter with at least three 10d common nails, the nearest no closer than 2⅜ in from the end of the rafter. On a 30 ft span at 6:12 the ridge rise is 7.50 ft, so the upper third runs from 5.00 ft to 7.50 ft above the plate. A compliant tie therefore sits in that band and is between 2 ft and 10 ft long — not the 14 ft member most people picture. The 4 ft spacing is generous relative to rafter spacing. At 24 in centres a tie on every second pair satisfies it; at 16 in centres every third pair does. The count on this page is driven by the spacing you enter, so enter 4 ft if you are checking compliance rather than fitting one at every pair. A ridge beam, a structural ridge, or a manufactured truss changes the question entirely. Where the ridge carries the rafters, the spread is resolved at the ridge and the tie is not doing that job. Trusses are designed as a system and must not be altered on site — you can size tcalculate roof trusses figures, but the bracing pattern comes from the truss designer. Eleven ties at 4 ft centres along a 40 ft building, each 14 ft long. Longer ties than Example 1 despite the smaller span, because the tie sits proportionally lower on a steeper roof. Eleven ties of 10 ft, in the band from 7.50 ft to the ridge at 11.25 ft. Compare that with the 16 ft member Example 2 produces at 3 ft — the same roof, a tie more than half as long again, sitting well below where the code wants it. On a hip roof the opposing member is not a common rafter but a jack, cut in a stepped series down the hip. If that is the roof you are framing, calculate jack rafter lengths separately — a collar tie does not apply to a hip end. Reference values for the pitches that set how fast the rafters converge. Every common pitch in one table: degrees, slope percentage, pitch factor and rafter length per 12 of run. 26.57°, a 50% slope and a pitch factor of 1.118 — the pitch used in most worked examples. 18.43° and a 33.33% slope. A moderate roof near the shallow end for many coverings. 14.04° and a 25% slope, common on porches, lean-tos and outbuildings. 9.46° and a 16.67% slope — the shallow end of what is usually still called a pitched roof. 33.69° and a 66.67% slope. A steep roof with noticeably more surface per square foot of footprint. 45°, a 100% slope and a pitch factor of 1.414, where rise equals run. A horizontal member that connects a pair of opposing rafters in the upper third of the roof. IRC R802.4.6 requires it to be at least 1 in by 4 in nominal and spaced no more than 4 ft on centre. Its job is to tie the two sides of the roof together and resist wind uplift. It is not the same as a rafter tie or ceiling joist, which sits at plate level and resists the outward thrust. It spans between the two rafters at whatever height it sits. Because the rafters converge towards the ridge, a higher tie is shorter than a lower one. On a 30 ft span at 6:12, a tie 4 ft above the plate is 14.00 ft long. The rafters rise at the pitch ratio, so at height h the horizontal distance from the plate to each rafter is h divided by the ratio. The tie length is the span minus twice that. At 6:12, 4 ft of height means 8 ft of horizontal travel on each side. The code puts a collar tie in the upper third of the attic space, so that band is where it belongs. Within the band, a lower tie is a little more effective against spread and a higher one leaves more headroom, but neither choice makes it a substitute for a rafter tie. This page computes the length for whatever height you enter; it does not decide the height for you. One at every rafter pair, or at a wider spacing if the design allows. This page takes the spacing as an input and counts from the building length. In practice ties are often fixed to every second or third pair rather than every one. Near the ridge it does very little, because the rafters are almost touching there and the member has almost no lever to work with. That is not a reason to drop it to plate level either — at plate level it stops being a collar tie and becomes a rafter tie, which is a different member with different sizing and a different place in the load path. No. A ceiling joist at plate level carries the horizontal thrust directly. A collar tie higher up helps, but it is not equivalent. Which one is required is a design question, and often both are used. Because ties are repeated along the building, one per pair, so they follow the length at your spacing. The span sets how long each one is; the length sets how many. No, only the length — and in the opposite direction to what most people expect. A steeper roof reaches a given height sooner, so the rafters are further apart at that height and the tie is longer. On a 30 ft span, a tie 4 ft above the plate is 14.00 ft at 6:12 and 19.33 ft at 9:12. No. A collar tie is in tension and its size depends on the thrust it has to resist, which comes from the roof load and the span. Sizing is a design question answered by a span table or an engineer. Shorter than most people expect, because the upper third is near the ridge. On a 30 ft span at 6:12 the ridge rise is 7.50 ft, so the compliant band runs from 5.00 ft to 7.50 ft and the tie is between 2 ft and 10 ft long. If your tie is 20 ft long on that roof, it is nowhere near the upper third. IRC R802.4.6 requires not less than 1 in by 4 in nominal, spaced not more than 4 ft on centre, located in the upper third of the attic space and fastened per Table R602.3(1). Ridge straps of at least 1¼ in by 20 gauge, fixed with three 10d common nails per rafter, may replace them. Your local code may differ; check the edition your building is inspected under. That depends on the design, not on this calculator. A structural ridge changes the load path — the ridge carries the rafters, so the outward thrust at the plate is largely resolved there. Whether a collar tie is still specified is up to the designer or the truss engineer. Do not delete bracing because a ridge beam is present without confirming it. The tie length is the span minus twice the horizontal travel of each rafter at the tie height. The travel is the height divided by the pitch ratio, which is the inverse of the rise calculation. The count follows the building length at your spacing. Nothing is assumed except the symmetric gable, which is stated. The code requirements quoted on this page are from IRC R802.4.6, which covers collar ties and ridge straps. That section sets the size, spacing and the upper-third location; the fastening schedule is in Table R602.3(1). Your jurisdiction may adopt a different edition, so confirm against the code your building is inspected under. The ridge rise sets the limit on how high a tie can go. The height calculator gives it with the eave and total heights.
What each collar tie input and result means
Field Unit What to enter Building span feet The full width across the gable, outside face to outside face. Not the half width — the calculator halves it internally. Pitch rise per 12 Roof pitch as rise over 12 of run. A 6:12 roof is 6. Degrees are not accepted here. Height above plate feet The vertical height from the top of the wall plate to where the tie sits. Must be below the ridge rise, or there is no gap left to span. Building length feet The distance along the ridge that the ties repeat along, not the span. Tie spacing feet Centre-to-centre spacing of the ties. Enter 4 for a code check, since 4 ft is the IRC maximum.
Result Unit What it means Collar tie length feet The cut length of a single tie at the height you entered, before any end allowance for the connection. Ties count How many run along the building at your spacing, including one at each end. This is the floor of length divided by spacing, plus one. Total length feet Ties multiplied by tie length. A member length before waste, not a purchase quantity. Rise to tie feet The height you entered, repeated back as a check against the ridge rise beside it. Ridge rise feet Height of the ridge above the plate. This is the ceiling on any tie height, and two-thirds of it is the bottom of the code's upper third. How to use the collar tie calculator
Collar tie formulas
travel each side = height ÷ ratio
tie length = span − 2 × travel
ridge rise = (span ÷ 2) × ratio
ties = ⌊length ÷ spacing⌋ + 1How collar tie height sets the tie length
Height above plate
Travel each side
Tie length
Share of ridge rise
In upper third?
1 ft 2.00 ft 26.00 ft 13% No 2 ft 4.00 ft 22.00 ft 27% No 3 ft 6.00 ft 18.00 ft 40% No 4 ft 8.00 ft 14.00 ft 53% No 5 ft 10.00 ft 10.00 ft 67% Yes 6 ft 12.00 ft 6.00 ft 80% Yes 7 ft 14.00 ft 2.00 ft 93% Yes 
Collar tie or rafter tie? The distinction that matters
What that means on a real roof
When the roof is engineered instead
Worked collar tie examples
Example 1 — 30 ft span at 6:12, tie at 4 ft
Example 2 — steeper pitch, tighter spacing
Example 3 — placing the tie where the code expects it
Collar tie limitations