Roof Slope Calculator

Read a roof slope as a percentage, a ratio in the form 1:X, an angle in degrees or a rise per 12 — or work out how much fall a given slope produces over a given run.

Quick answer: a rise of 1.5 ft over a run of 20 ft is a 7.5% slope, a ratio of 1:13.3, 4.29°, and 0.9:12 — a very shallow roof.

  • Four ways to express one slope
  • Fall over a run
  • Imperial and metric

Roof slope calculator inputs and results

How far the surface climbs over the run; the same unit on both sides cancels out in the ratio.

The horizontal distance the rise happens over. On a low-slope roof, use the longest run you can measure — a short run magnifies the error.

Rise and runhorizontal runvertical risepitch
Measure the horizontal run and the vertical rise on the same plane; both feed the numbers above. → rise per 12

Results

Roof slope
7.50%
1.5 ft rise over 20 ft run
Rise per 12
0.9:12
Angle
4.29°
Ratio
1:13.3
Fall per 10 ft
9 in
Pitch factor
1.003
Slope length
20.1 ft

Slope is a property of the surface and says nothing about whether a covering is permitted at that slope.

Rise per 12 is the same slope written the way roofing products quote it. The 1:X ratio is the same number upside down, and the pitch factor converts flat lengths and areas into sloped ones.

Show calculation

Roof slope geometry

7.50% · 4.29°

Rise over run is the tangent of the angle. The percentage is that same ratio multiplied by 100.

What this roof slope calculator works out

A slope can be described four ways, and different documents use different ones. A product data sheet might say "minimum 2:12". A drainage drawing might say "1.5%". A set of architectural drawings might say "4°" — and if degrees are what you have, the roof angle calculator starts from that end. They can all describe the same roof, and converting between them by hand is where mistakes happen.

This page converts in one step. Give it a rise and a run and it returns the slope as a percentage, a rise per 12, an angle in degrees and a unit ratio. If your document works in pitch rather than slope, the roof pitch calculator presents the same numbers the other way round.

The second mode runs the calculation the other way. Give it a run and a slope and it tells you the total fall over that distance — the number you need when setting out a gutter, a drainage channel or a shallow roof to a designed fall.

A low-slope commercial roof with a grey membrane and a metal drainage scupper at the perimeter.
Low-slope roofs rely on a precise fall so water reaches the outlet instead of standing on the membrane.
Percentages and degrees are not the same scale. A 7.5% slope is 4.29°, not 7.5°. The two only coincide at zero. At 100% the slope is 45°.

What each roof slope input and result means

One ratio in, four descriptions out.

The inputs and results.
FigureWhat it meansWhere it comes from
Vertical riseHeight gained over the runMeasured, or the fall stated on a drawing
Horizontal runLevel distance the fall happens overMeasured
Run lengthAn optional distance to report the fall over — 10 ft by defaultYour choice, for setting out
SlopeThe ratio as a percentageCalculated
Rise per 12The same ratio as pitch, for roofing documentsCalculated
AngleThe same ratio in degreesCalculated
Pitch factorThe multiplier that turns a plan length into a length along the slope — 1.003 on a shallow roof, 1.414 at 45°Calculated
Slope lengthThe distance along the slope for the run you entered, rather than the level distanceCalculated

The first four figures describe one slope, so if they disagree the arithmetic is wrong rather than the roof. The last two are derived from it: the pitch factor is the same number every slope page quotes, and the slope length applies it to the run you entered.

How to use the roof slope calculator

  1. Choose a mode. Use Rise & run when you have two measurements. Use Fall over a run when you have a design slope and a distance.
  2. Enter the measurements in any consistent unit. Slope is a ratio, so the unit cancels — but rise and run must match.
  3. Read the four forms in the results. Whichever one your document uses is there. The pitch factor and slope length underneath convert the angle into lengths, which is what you need before ordering anything.
  4. Check the diagram to confirm the proportions look like the roof you are describing. A shallow slope should look shallow.

Roof slope formulas

One ratio, expressed four ways.

ratio = rise ÷ run
slope (%) = ratio × 100
rise per 12 = ratio × 12
angle = atan(ratio) × 180 ÷ π
unit ratio = 1 : (1 ÷ ratio)
fall over a run = run × ratio
pitch factor = √(1 + ratio²)
slope length = run × pitch factor

Units. Every conversion here is a ratio, so it is dimensionless — 7.5% is 7.5% whether the roof is measured in feet or metres. Only the fall figure carries a unit, and it inherits whichever one the run was entered in.

The four forms of one ratio

Formula. Ratio = rise ÷ run. Slope (%) = ratio × 100. Rise per 12 = ratio × 12. Angle = atan(ratio) × 180 ÷ π. Unit ratio = 1 : (1 ÷ ratio).

Variables. Rise and run in any consistent length unit; ratio dimensionless; slope in percent; rise per 12 in the same unit as the run; angle in degrees.

Calculation logic. Everything descends from the single ratio. The percentage multiplies it by 100, the rise per 12 multiplies it by 12, and the unit ratio is its reciprocal — those three are bookkeeping, not geometry. Only the angle involves trigonometry, because an angle is a non-linear function of the ratio while the others are proportional to it.

Example. 1.5 ÷ 20 = 0.075. × 100 = 7.50%. × 12 = 0.9:12. atan(0.075) = 4.29°. 1 ÷ 0.075 = 13.3, so 1:13.3.

Result interpretation. The four figures are the same slope, so a discrepancy between them is always an arithmetic error rather than a measurement one. If you are missing one of the two measurements rather than the conversion, the rise and run calculator solves for it.

Worked roof slope examples

Example 1 — a shallow roof measured in feet

A porch roof rises 1.5 ft over a 20 ft run.

Ratio
1.5 ÷ 20 = 0.075
Slope
0.075 × 100 = 7.50%
Rise per 12
0.075 × 12 = 0.9:12
Angle
atan(0.075) = 4.29°
Unit ratio
1 : (1 ÷ 0.075) = 1 : 13.3
Pitch factor
√(1 + 0.075²) = 1.003
Slope length
20 × 1.003 = 20.06 ft along the slope

At 0.9:12 this is a very shallow roof, well below the usual range for pitched coverings. That is a product question, not a geometry one, but it is worth checking before specifying a covering.

slope = (1.5 ÷ 20) × 100 = 7.50%

Example 2 — fall over a 30 ft gutter run at 2%

A specification calls for a 2% fall over a 30 ft gutter run.

Ratio
2 ÷ 100 = 0.02
Total fall
30 × 0.02 = 0.6 ft
In inches
0.6 × 12 = 7.2 in
Angle
atan(0.02) = 1.15°
Rise per 12
0.02 × 12 = 0.24:12

So one end of the run sits 7.2 in lower than the other. Whether 2% is the right figure for that gutter is a manufacturer or code question — this is only the arithmetic.

fall = 30 ft × 0.02 = 0.6 ft = 7.2 in

Roof slope, fall and drainage

On a pitched roof, slope is mostly about shedding water and staying within what the covering is rated for. On a low-slope roof, slope is about getting water to a specific place: an outlet, a scupper or a gutter. Setting a gutter line to a fall is its own calculation, and the gutter slope calculator works in that sense.

That second job is where the fall figure matters more than the percentage. Two roofs can both be "1%" but if one has a 60 ft run to an outlet and the other has 10 ft, the actual height difference is six times larger, and so is the depth of the ponding that forms if the outlet blocks.

Measuring slope on a low-slope roof is harder than it looks. The rise is small, so a short run magnifies measurement error: 1/4 in of misreading over 2 ft is a slope error of about 1%, which is the whole fall on many flat roofs. Measure over the longest run available.

Common slope expressions side by side.
Slope (%)Rise per 12AngleFall over 10 ft
1.00%0.12:120.57°1.20 in
2.00%0.24:121.15°2.40 in
3.00%0.36:121.72°3.60 in
5.00%0.60:122.86°6.00 in
8.33%1.00:124.76°10.00 in
12.50%1.50:127.13°15.00 in
16.67%2.00:129.46°20.00 in
25.00%3.00:1214.04°30.00 in
33.33%4.00:1218.43°40.00 in
50.00%6.00:1226.57°60.00 in

Fall over 10 ft is shown in inches because that is how it is usually set out on site. The 25% row is worth remembering: it is exactly 3:12, the pitch where many shallow coverings stop being ordinary, and the 3/12 roof pitch reference sets out what that means in practice.

A spirit level and straightedge laid on a sloping roof surface with a wedge gauge, checking the fall.
Checking a shallow fall with a level and a wedge. The longer the straightedge, the smaller the measurement error.

Roof slope calculator limitations

  • Straight-line slope. Real roofs deflect, and low-slope roofs can pond. The geometric slope is not the as-built slope.
  • One plane. A roof with several planes at different slopes needs a calculation for each.
  • No code minimum. This page does not know what slope your covering, your jurisdiction or your drainage design requires.
  • No drainage capacity. Slope is one factor in whether a roof drains; outlet size, gutter capacity and rainfall intensity matter too.
  • No area. The same ratio is the basis of the pitch factor that converts plan area into roof area, which the pitch multiplier calculator applies.
  • Slope is not the same as fall. Slope is the ratio or percentage; fall is the height difference over a given length. One converts to the other only when you know the length.
  • Built slope is not design slope. A roof or gutter specified at 2% can be built at 1.4% and still look right, which is why the fall is checked with a level rather than assumed.

Roof Pitch Resources and Guides

Each of these pages gives the full set of equivalent values for one pitch.

Frequently asked questions

Three ways, all describing the same angle. As a percentage it is rise divided by run times 100, so a 6:12 roof is 50%. As a ratio it is rise to run, written 6:12 or 1:2. As an angle it is the degrees between the roof plane and horizontal, which for 6:12 is 26.57°. This page shows all three at once so you can match whichever form your drawing, specification or product data sheet uses.

In common trade use they are interchangeable. Strictly, pitch is usually written as rise per 12 of run (6:12) and slope as a percentage or a ratio (50%, 1:2). One trap: some technical references define pitch as rise over the full span, which halves the number for the same roof. If a drawing gives a pitch that looks half what you expected, check which definition it is using.

That depends on the covering, and the answer comes from the product's published installation instructions and the building code adopted where the building is. There is no single figure that applies to every roof. This calculator tells you what fall a given slope produces over a given run. It does not tell you what slope you are required to have, because that is a product and code question rather than a geometric one.

Because water has to leave. Standing water stresses the waterproofing, collects debris and, in cold climates, freezes and expands. A roof that drains fully lasts longer than one that holds water in shallow ponds. The fall also determines where water goes, which is what gutters, outlets, scuppers and internal drains are positioned around. A flat-looking roof still has a designed fall, even when it is too shallow to see.

Multiply the percentage by 12 and divide by 100. A 25% slope is 25 × 12 ÷ 100 = 3, so it is 3:12. Going the other way, multiply the rise per 12 by 100 and divide by 12. A 4:12 roof is 4 × 100 ÷ 12 = 33.33%.

Measure a horizontal run and the vertical rise over that run, then divide. In an attic, hold a level against the underside of a rafter, mark 12 inches, and measure the vertical gap at the mark — that gives the rise per 12 directly. On a low-slope roof, a straightedge and a level work the same way over a longer run, which is more accurate because the fall is small. A 1 in 8 ft fall is easy to miss over 2 ft.

Yes, for the geometry. Enter the run and the slope and the calculator returns the total fall over that length, which is what you need to set the height difference between the two ends of a gutter run. What it will not tell you is the slope a gutter should be installed at. That comes from the gutter manufacturer and local practice, so check before setting out.

No. A 2% slope is a rise of 2 units per 100 units of run, which is 1.15°. Percentages and degrees are different scales and the gap widens as the slope increases — a 100% slope is 45°, not 100°. The calculator converts between them so you do not have to remember the relationship.

Because a unit ratio is easier to compare than a pair of measurements. A slope of 1:4 means one unit of rise for every four units of run, whatever the units are. It is the same relationship as 3:12 — divide both sides of 3:12 by 3 and you get 1:4.

14.04°. A 25% slope means the rise is a quarter of the run, so the tangent of the angle is 0.25 and the arctangent is 14.04°. In roof terms that is exactly 3:12, because 3 ÷ 12 is also 0.25. That is the useful thing to remember about percentages: a slope percentage is simply the pitch expressed as rise ÷ run × 100, so 3:12, 25% and 14.04° are three descriptions of one roof.

80 mm. Two per cent of 4,000 mm is 80 mm, so one end sits 80 mm lower than the other over that run. This is the conversion that matters on site, because slopes are specified as percentages and built with a level: a 4 m straight edge with an 80 mm packer under one end gives exactly 2%. Note that the fall is measured along the horizontal run, not along the sloping surface, which for a 2% slope makes a difference of 0.02% — negligible here, but not on a steep roof.

Anything at or below about 2%, which is ¼:12 — the design slope the code requires for built-up roofing, and the figure most single-ply membranes are rated from. A flat roof is therefore never level: it has a small, specified fall so that water leaves rather than stands. Below that you are into "ponding" territory, where the roof holds water until it evaporates, and no membrane is designed for it.

Where these numbers come from

Every conversion on this page is trigonometry. The ratio is rise over run, the angle is its arctangent, and the percentage and the rise per 12 are the same ratio scaled by 100 and by 12. Nothing here depends on a manufacturer's table.

Two things are not arithmetic and are deliberately not stated as figures:

  • Minimum slope for a covering. This comes from the product's published installation instructions and from the building code adopted in your area.
  • Required fall for drainage. This comes from the drainage design, the manufacturer's instructions and local practice, and it varies with the system.

No claim on this page has been reviewed or endorsed by any code body, manufacturer or trade association.

Before you build to it

Four checks before the slope is fixed on a drawing.

  • Know which form the document uses. Percent, ratio, degrees and rise per 12 look similar at a glance and are not interchangeable.
  • Check the covering's minimum. A slope that suits one product can be below the limit for another, and the limit is published per product.
  • Set the fall out, not the angle. On site a fall is easier to check over a long run, and it is what the drawings usually specify.
  • Treat drainage as separate. Slope gets water to the outlet; the outlet still has to be sized for the area and the rainfall.

The conversion is exact. Whether the slope is acceptable for the covering is a product and code question this page does not answer.

What does that slope do to the area?

The ratio becomes a pitch factor, and the factor turns a footprint into roof surface.

Back to the calculator
Scroll to Top