Soffit Lighting Calculator

Plan a line of soffit downlights: fittings at the spacing you want, the spacing you actually get, and the load the run adds to the circuit.

Quick answer: a 120 ft run at 8 ft spacing needs 16 downlights — 15 gaps, with one fitting at each end. At 8 W each that is 128 W, or 1.07 A at 120 V.

  • Count from run length and spacing
  • Spacing actually achieved
  • Total load in watts and amps

Soffit lighting inputs and results

Enter the fitting wattage from its data; the load figure is a check rather than a circuit design.

Eave, gutter and fasciaeave runsoffit widthroof plane
Take the eave run along the eave and the soffit width down the run before you start. → downlights
Downlights
16
8.0 ft apart · 15 sq ft each · 128 W total
Spacing achieved
8.0 ft
Area per fitting
15 sq ft
Total load
128 W
Current
1.07 A

Circuit design, cable sizing and switching belong to a qualified electrician.

Show calculation

Soffit Lighting Inputs and Results Explained

Five inputs: the run, the spacing you want, and three figures from the fitting and the circuit.

  • Soffit run (ft): the length being lit on one elevation. Several elevations are calculated separately and added.
  • Desired spacing (ft): how far apart you want the fittings. Capped at 30 ft, beyond which a line of downlights stops reading as a continuous run.
  • Soffit width (ft): the depth of the overhang, used only to work out the area each fitting serves.
  • Watts per fitting: the rated wattage of one fitting from its data, not a nominal lamp rating.
  • Circuit voltage (V): the supply voltage, typically 120 V.

The calculator stops if the spacing is longer than the run, because two fittings at the ends is then all that fits and the arithmetic would divide by zero.

ResultUnitWhat it represents
FittingscountWhole fittings needed: the number of gaps, plus one for the far end. The figure at the top of the results.
Spacing achievedftThe distance you will actually mark out. Always at or below the spacing you asked for.
Area per fittingsq ftSoffit area divided by the fitting count. A coverage proxy, not a photometric figure.
Total loadWFittings multiplied by the watts per fitting. A check on the circuit, not a design for it.
CurrentATotal load divided by the voltage. The same check expressed as current.

Area per fitting is the one result that is easy to misread. It says how much soffit each fitting sits above, not how much light it puts on the ground.

What This Calculator Works Out

Soffit lighting is a line of fittings along the eave, and the thing that decides the count is how far apart you want them. This calculator takes the run and the spacing, adds the end fitting, and reports the spacing you actually get once the count is a whole number.

It also totals the electrical load, which is a check rather than a design: enough to see whether a run of fittings is trivial or whether it needs thinking about.

It does not design the circuit, choose the fitting, or model the light. Cable sizing, protection and switching belong to a qualified electrician, and how the light falls on the ground depends on the fitting's optics rather than on how much soffit it sits above.

The lighting shares its run with the rest of the roof edge. Where that edge also needs metal at the fascia or a wall junction, the flashing estimator totals those items separately.

Recessed downlights set into the soffit under a roof overhang at dusk, spaced evenly along the eave and lighting the wall below.
The spacing is the visible design decision. The count follows from it, plus one for the far end.

How to Use the Soffit Lighting Calculator

Decide the spacing first, then let the count follow.

  1. Enter the run. Give the soffit length that is being lit, one elevation at a time.
  2. Choose the spacing. Enter the distance you want between fittings; the count and the achieved spacing both follow from it.
  3. Enter the soffit width. This only affects the area-per-fitting figure, so a rough value is enough if the width is constant.
  4. Enter the fitting and the voltage. Take the wattage from the product data and the voltage from the supply.
  5. Read the result. Compare the total watts and amps with the circuit, and check the achieved spacing before marking out.

If the spacing achieved differs noticeably from the figure you entered, the run does not divide evenly. That is normal, and the achieved figure is the one to mark from.

How to Measure the Run and Mark the Spacing

The measurement is simple; the marking out is where the job goes wrong.

One elevation at a time

Measure each straight run separately — the front eave, each side, a porch. Adding two elevations into one figure gives a count that assumes fittings span the corner, and none of them can.

The run is the soffit, not the roof

Use the length of soffit being lit, which is the same run the soffit panels follow. Where the soffit is already being ordered, the soffit estimator gives that run directly, so the two calculations start from the same measurement.

Set the spacing from the fitting, not from habit

The right spacing depends on the beam angle and the mounting height, and on what the light is meant to do — wash a wall, mark a path, or light a door. There is no universal figure, which is why it is an input.

Mark from one end and check the last gap

Divide the run by the gap count from the calculator, not by the spacing you asked for. Marking at the requested spacing and finding a short gap at the far end is the standard way to end up with an uneven run.

Check what is above before you cut

A recessed fitting needs depth and clearance. A rafter, a joist or a service running along the soffit will decide some positions for you, and it is better to find that at marking-out than after the hole is cut.

Check the vent layout at the same time

On a vented soffit, the vent panels and the light positions compete for the same surface. Mark both on the same drawing before either is cut, which is the subject of the next section.

Where the run ends

The far end is usually the corner or the fascia return, and the outer edge of the soffit is the fascia itself. If that board is being measured or replaced at the same time, the roof fascia length calculator covers it on the same run.

Formula and Calculation Logic

gaps = ⌊ run ÷ spacing ⌋
fittings = gaps + 1
spacing achieved = run ÷ gaps
area per fitting = run × width ÷ fittings
load (W) = fittings × watts per fitting
current (A) = load ÷ voltage

The variables

  • L — soffit run, feet.
  • s — requested spacing, feet.
  • w — soffit width, feet.
  • P — watts per fitting.
  • V — circuit voltage.

Why it is gaps plus one, not run divided by spacing

Fittings sit at both ends of the run, so the count is one more than the number of spaces between them — the same reason a fence needs one more post than it has bays. A 120 ft run at 8 ft is 15 gaps and therefore 16 fittings, not 15. This is the single most common surprise on the page.

Why the floor is used

A partial gap at the end of the run is not a gap; it is the remainder. Taking the floor gives the number of complete gaps that fit, and the remainder is absorbed by making every gap slightly smaller.

Why the achieved spacing is always shorter

Dividing the run by the gap count spreads the remainder across every gap, so the spacing you mark is the requested spacing or less — never more. On 120 ft at 7 ft, seventeen complete gaps do not fit, so you get 17 gaps at 7.06 ft each. The fittings end up slightly closer together than asked, which is the harmless direction.

Why area per fitting is not a light level

Dividing the soffit area by the fitting count gives the surface each fitting sits above. That is useful for comparing one layout with another, but it says nothing about illuminance, beam angle or how the light lands. Do not read it as a photometric figure.

Why the load is a check, not a design

Fittings times watts gives the connected load, and load divided by voltage gives the current. That is enough to see whether the run is a trivial addition to an existing circuit or something that needs its own. Cable sizing, protective device rating, volt drop and switching are a separate design, and on a lighting circuit they are not optional.

A complete calculation

With L = 120 ft, s = 8 ft, w = 2 ft, P = 8 W and V = 120 V: gaps = ⌊120 ÷ 8⌋ = 15; fittings = 16; spacing achieved = 120 ÷ 15 = 8.0 ft; area each = 120 × 2 ÷ 16 = 15 sq ft; load = 128 W; current = 1.07 A.

The Vent Conflict

On a vented roof the soffit is the intake for attic ventilation, and a recessed downlight cuts a hole through it. Each fitting removes vent area, and the ventilation design assumed that area was there.

The effect is not always small. A run of sixteen fittings at 4 in diameter removes about 1.4 sq ft of soffit surface, and if that surface was vented, it removes net free area in proportion. On a roof whose intake was sized tightly, that is enough to change the balance.

The practical answer is to plan the two together: mark the vent panel layout and the light positions on the same drawing, keep fittings over solid sections where possible, and recheck the intake area afterwards. The calculate soffit vents works out how much intake the roof needs and how much the remaining vented panels provide.

Mark out before you cut. A downlight in the wrong place cannot be moved without a patch, and a fitting over a vent panel is the most common regret on this job.
A recessed downlight fitted into a soffit panel, with the trim ring flush against the underside.
Each fitting removes a circle of soffit surface. On a vented soffit that is also a loss of intake area.

Worked Examples

Example 1 — 120 ft at 8 ft spacing

Gaps
⌊120 ÷ 8⌋ = 15
Fittings
15 + 1 = 16
Spacing achieved
120 ÷ 15 = 8.0 ft
Area each
120 × 2 ÷ 16 = 15 sq ft
Load
16 × 8 = 128 W
Current
128 ÷ 120 = 1.07 A
fittings = floor(120 ÷ 8) + 1 = 16

Example 2 — the same run at 6 ft spacing

Gaps
⌊120 ÷ 6⌋ = 20
Fittings
21
Spacing achieved
6.0 ft
Load
21 × 8 = 168 W
Current
1.40 A

Tighter spacing adds five fittings and 40 W. On LED fittings the electrical effect is trivial; the cost is in the fittings and the extra holes in a vented soffit.

fittings = floor(120 ÷ 6) + 1 = 21

Example 3 — 120 ft at 7 ft, which does not divide

Gaps
⌊120 ÷ 7⌋ = ⌊17.14⌋ = 17
Fittings
18
Spacing achieved
120 ÷ 17 = 7.06 ft
Area each
120 × 2 ÷ 18 = 13.3 sq ft
Load
18 × 8 = 144 W
Current
1.20 A

The requested 7 ft is not achieved — the fittings go in at 7.06 ft. That looks like rounding noise, but it is the difference between a run that closes evenly at both ends and one that leaves a short gap at the corner. Mark from 7.06 ft, not from 7.

fittings = floor(120 ÷ 7) + 1 = 18
RunSpacingFittingsArea eachLoad at 8 W
60 ft6 ft1111 sq ft88 W
60 ft8 ft815 sq ft64 W
120 ft6 ft2111 sq ft168 W
120 ft8 ft1615 sq ft128 W
120 ft10 ft1318 sq ft104 W

Assumes a 2 ft soffit width. Tighter spacing raises both the count and the load, and shrinks the area each fitting serves.

Limitations and assumptions

  • Even spacing assumed. Fittings grouped around a door, or deliberately omitted over a window, are not modelled.
  • One elevation. Several runs should be calculated separately and added, because the count does not carry across a corner.
  • No circuit design. Cable sizing, protective devices, volt drop, earthing and switching are excluded. Those are a qualified electrician's work.
  • No vent area deduction. The effect of each hole on intake is described, not calculated.
  • No light output modelling. Area per fitting is not a photometric figure, and neither is the fitting count.
  • Wattage is yours. Use the fitting data, not a nominal lamp rating, and check whether the figure includes the driver.
  • No structural check. Whether a rafter or trimmer is in the way of a fitting is a site question.
  • No weathertightness check. The fitting must be rated for the location it is installed in, which is a product decision.

Two neighbouring items sit outside the count. The metal that caps the outer edge of the soffit is ordered by the same run, and the drip edge calculation covers it. Where the fascia itself is being clad rather than replaced, the roof fascia wrap calculator covers that material.

Frequently asked questions

Divide the run by the spacing you want, round that down to whole gaps, and add one for the far end. A 120 ft run at 8 ft is 15 gaps and therefore 16 fittings. The count is set by the spacing rather than by a rule about how many lights a soffit should have.

Because fittings sit at both ends of the run as well as between them. There are 15 spaces, and 16 points that bound them — the same reason a fence needs one more post than it has bays. Dividing the run by the spacing gives the number of gaps, not the number of fittings.

It depends on the fitting's beam angle, the mounting height and what the light is for. A narrow beam washing a wall wants closer spacing than a wide beam marking a path. There is no universal figure, which is why the calculator takes it as an input rather than suggesting one.

Because the run rarely divides exactly. The calculator takes the whole number of gaps that fit and spreads the remainder across them, so the spacing you mark is slightly less than you asked for. On 120 ft at 7 ft you get 17 gaps at 7.06 ft. Mark from the achieved figure, not the requested one.

No. It reports connected load and current so you can see the scale of the addition. Cable sizing, the protective device, volt drop, earthing and switching are a circuit design, and on a lighting circuit they are not optional. That work belongs to a qualified electrician.

The soffit area divided by the number of fittings, so it describes how much surface each one sits above. It is a useful way to compare one layout with another, but it is not a light level — it says nothing about beam angle, illuminance or how the light lands on the ground.

They can. On a vented roof the soffit is the intake, and every recessed fitting removes a circle of vented surface. Sixteen 4 in fittings remove about 1.4 sq ft, which is small in absolute terms but matters on a roof whose intake was sized tightly. Keep fittings over solid panels where you can and recheck the intake afterwards.

Yes. The arithmetic is a line of fittings along a run, so any horizontal surface with a straight edge works the same way. Calculate each run separately and add the fittings, because the count does not carry across a corner.

The rated wattage of the complete fitting from its data sheet, not the wattage of a lamp you might fit into it. On an integrated LED fitting that is the whole unit; on a fitting with a separate driver, check whether the published figure is the fixture load or the lamp load.

Not in one calculation. The calculator assumes even spacing, so a run with fittings grouped over a door has to be worked out in sections and added. That is also how you would mark it out, so the two agree.

No. The load figure is the connected load at full output. Dimming reduces consumption but does not change the circuit's design load, and dimmer compatibility with LED drivers is a product question rather than a quantity one.

The fitting count and spacing are unchanged. The current figure changes with the voltage you enter, and on a low-voltage system the transformer or driver becomes the limiting component rather than the circuit. The load calculation here is still only a check.

Where these numbers come from

The calculation is a floor, an addition, three divisions and a multiplication. Every input comes from your measurement, the fitting's data or the supply — nothing is assumed about how far apart lights should be.

The electrical side is not arithmetic and is not covered here. What governs it is the wiring code adopted where the building stands and the fitting's own installation instructions: cable size, protective device rating, volt drop, earthing and the suitability of the fitting for a damp or outdoor location. Those documents are not reproduced on this page and the result here is not a substitute for them.

The ventilation side is a design question rather than a document. How much intake a roof needs, and how much of it the remaining vented soffit provides, comes from the roof's ventilation design and the product data for the vent panels. That calculation is deliberately left to the soffit vent calculator rather than duplicated here.

Worth being direct about the gap: there is no government or industry-association document that specifies soffit light spacing. Spacing follows from the fitting's optics and the effect wanted, which is why it is an input. Any page quoting a single national figure for it is quoting a rule of thumb, not a requirement.

The arithmetic on this page establishes a fitting count and a load check. It does not establish that the circuit is safe, that the fitting suits the location, or that the roof remains adequately ventilated afterwards.