Roof Pitch Chart: Complete Guide to Roof Slope, Angles & Rafter Length
Roof pitch describes how much a roof rises vertically over a horizontal distance. It is one of the key measurements used when planning roof geometry, estimating surface area, and calculating rafter lengths. This chart covers common slopes from 1/12 through 24/12.
Quick answer: 4/12 is 18.43° with a 33.33% slope and a pitch factor of 1.054. 6/12 is 26.57°, 50% and 1.118. 8/12 is 33.69°, 66.67% and 1.202. 12/12 is exactly 45°, 100% and 1.414.
- 24 pitches from 1/12 to 24/12
- Hip and valley factors included
- Formulas shown for every column
Roof Pitch Chart: 1/12 to 24/12
The table uses the rise-over-12-run convention. For example, a 6/12 roof rises 6 inches vertically for every 12 inches of horizontal run.
| Roof Pitch | Angle | Slope | Pitch Factor | Hip/Valley Factor | Rafter per 12" Run | OSHA Slope Class |
|---|---|---|---|---|---|---|
| 1/12 | 4.76° | 8.33% | 1.003 | 1.417 | 12.04" | Low-slope |
| 2/12 | 9.46° | 16.67% | 1.014 | 1.424 | 12.17" | Low-slope |
| 3/12 | 14.04° | 25.00% | 1.031 | 1.436 | 12.37" | Low-slope |
| 4/12 | 18.43° | 33.33% | 1.054 | 1.453 | 12.65" | Low-slope |
| 5/12 | 22.62° | 41.67% | 1.083 | 1.474 | 13.00" | Steep-slope |
| 6/12 | 26.57° | 50.00% | 1.118 | 1.500 | 13.42" | Steep-slope |
| 7/12 | 30.26° | 58.33% | 1.158 | 1.530 | 13.89" | Steep-slope |
| 8/12 | 33.69° | 66.67% | 1.202 | 1.563 | 14.42" | Steep-slope |
| 9/12 | 36.87° | 75.00% | 1.250 | 1.601 | 15.00" | Steep-slope |
| 10/12 | 39.81° | 83.33% | 1.302 | 1.641 | 15.62" | Steep-slope |
| 11/12 | 42.51° | 91.67% | 1.357 | 1.685 | 16.28" | Steep-slope |
| 12/12 | 45.00° | 100.00% | 1.414 | 1.732 | 16.97" | Steep-slope |
| 13/12 | 47.29° | 108.33% | 1.474 | 1.781 | 17.69" | Steep-slope |
| 14/12 | 49.40° | 116.67% | 1.537 | 1.833 | 18.44" | Steep-slope |
| 15/12 | 51.34° | 125.00% | 1.601 | 1.887 | 19.21" | Steep-slope |
| 16/12 | 53.13° | 133.33% | 1.667 | 1.944 | 20.00" | Steep-slope |
| 17/12 | 54.78° | 141.67% | 1.734 | 2.002 | 20.81" | Steep-slope |
| 18/12 | 56.31° | 150.00% | 1.803 | 2.062 | 21.63" | Steep-slope |
| 19/12 | 57.72° | 158.33% | 1.873 | 2.123 | 22.47" | Steep-slope |
| 20/12 | 59.04° | 166.67% | 1.944 | 2.186 | 23.32" | Steep-slope |
| 21/12 | 60.26° | 175.00% | 2.016 | 2.250 | 24.19" | Steep-slope |
| 22/12 | 61.39° | 183.33% | 2.088 | 2.315 | 25.06" | Steep-slope |
| 23/12 | 62.45° | 191.67% | 2.162 | 2.382 | 25.94" | Steep-slope |
| 24/12 | 63.43° | 200.00% | 2.236 | 2.449 | 26.83" | Steep-slope |
Chart notes:
- Pitch Factor converts horizontal measurements into measurements along a simple sloped roof surface.
- Hip/Valley Factor is a multiplier for a 45-degree plan-direction hip or valley rafter on a regular roof geometry.
- Rafter length is calculated for a 12-inch horizontal common-rafter run.
- OSHA class uses the US definition: low-slope is 4:12 or less; steep-slope is greater than 4:12. This classification does not, by itself, describe every fall-protection requirement.
- Values are rounded for reference. Actual construction measurements may require additional framing details.
How to Read a Roof Pitch Chart
A roof pitch chart presents several measurements that describe the same roof geometry in different ways. Each value has a particular purpose when estimating roof area, comparing slopes, or calculating framing dimensions.
1. Roof Pitch: Rise Over Run
Roof pitch is commonly written as a ratio such as 4/12, 6/12, or 12/12. The first number represents vertical rise, while 12 represents the horizontal run.
For example:
- 2/12: 2 inches of rise over 12 inches of run.
- 4/12: 4 inches of rise over 12 inches of run.
- 6/12: 6 inches of rise over 12 inches of run.
- 12/12: 12 inches of rise over 12 inches of run.
A higher rise over the same horizontal run produces a steeper roof.
2. Roof Angle: Degrees
Roof angle measures the inclination of the roof surface relative to the horizontal plane.
| Roof Pitch | Roof Angle |
|---|---|
| 2/12 | 9.46° |
| 3/12 | 14.04° |
| 4/12 | 18.43° |
| 6/12 | 26.57° |
| 8/12 | 33.69° |
| 10/12 | 39.81° |
| 12/12 | 45.00° |
Degrees are useful when comparing roof profiles or working with angle-based measurements.
3. Slope Percentage
Slope percentage expresses the vertical rise as a percentage of the horizontal run. For example, a 6/12 roof has a 50% slope because its rise is half its run. A 12/12 roof has a 100% slope because its rise and run are equal.
4. Pitch Factor: Roof Surface Area Multiplier
Pitch Factor helps convert a horizontal roof footprint into the sloped surface area of a simple roof plane. For example, a 6/12 roof has a pitch factor of approximately 1.118.
If a simple roof has a horizontal footprint of 1,000 square feet and a consistent 6/12 slope:
This estimate does not automatically include overhangs, valleys, dormers, or other roof geometry.
5. Hip and Valley Rafter Factor
Hip and valley rafters follow a diagonal direction in the roof plan. Their horizontal projection is different from the horizontal run of a common rafter. The hip and valley factor accounts for this diagonal plan direction along with the roof rise.
For a regular 45-degree plan-direction hip or valley, the factor can be used to estimate the theoretical rafter length from its horizontal plan run.
6. Common Rafter Length
Common rafter length is the theoretical distance along the sloped rafter for a given horizontal run. For example, a 6/12 roof has a rafter factor of approximately 1.118. For a 12-inch horizontal run:
This is a geometric length, not a complete cutting measurement. Ridge connections, eave overhangs, seat cuts, and other framing details must be considered separately.
Visual Roof Pitch Comparison
Roof pitch becomes easier to understand when different slopes are shown using the same horizontal base. A 2/12 roof has a relatively shallow profile, while a 6/12 roof rises more noticeably. A 12/12 roof has equal rise and run, producing a 45-degree angle.
Six roof pitches drawn to the same horizontal run
GeometryEach profile rises from the same baseline over the same horizontal run, so the change in steepness is directly comparable. Rise and run are drawn to scale.
How Roof Pitch Changes the Roof Area
A roof with a steeper slope generally has a larger sloped surface area than a horizontal footprint with the same plan dimensions. The pitch factor provides a simple way to estimate that difference.
Consider a roof with a horizontal footprint of 1,000 square feet:
| Roof Pitch | Pitch Factor | Estimated Sloped Area |
|---|---|---|
| 2/12 | 1.014 | 1,014 sq ft |
| 3/12 | 1.031 | 1,031 sq ft |
| 4/12 | 1.054 | 1,054 sq ft |
| 5/12 | 1.083 | 1,083 sq ft |
| 6/12 | 1.118 | 1,118 sq ft |
| 8/12 | 1.202 | 1,202 sq ft |
| 10/12 | 1.302 | 1,302 sq ft |
| 12/12 | 1.414 | 1,414 sq ft |
These values assume a simple roof with one consistent slope and no additional geometric features. For a complete roofing estimate, the actual roof shape, overhangs, valleys, dormers, and material waste must also be considered.
To apply this to your own footprint, the roof area calculator converts plan dimensions and pitch into a sloped area, and the roofing square calculator carries that area through to squares and bundles.
Roofing Material Compatibility by Roof Pitch
Roof pitch can affect which roofing systems are suitable for a project. Different products have different minimum slope requirements and installation procedures. A material that works on a steep roof may not be appropriate for a low-slope application. Always check the installation instructions for the exact product being considered.
Asphalt Shingles on Low-Slope Roofs
Asphalt shingles have specific slope requirements. The Asphalt Roofing Manufacturers Association (ARMA) explains that asphalt shingles may be installed on slopes from 2:12 to less than 4:12 when the required special installation procedures are followed. It advises against installing them below 2:12.
The International Residential Code also includes additional underlayment requirements for asphalt shingles in the 2:12 to less than 4:12 range. This means that a 3/12 roof and a 6/12 roof may require different underlayment procedures even when the same general shingle product is being considered.
Check Product-Specific Requirements
Before choosing a roofing system, review:
- The product’s minimum and maximum approved slope.
- Required underlayment type and installation method.
- Fastening and sealing requirements.
- Local building-code provisions.
- Warranty conditions and manufacturer instructions.
Do not assume that every metal panel, membrane, tile, slate, or shingle product has the same permitted pitch range.
Hip and Valley Rafter Factor Explained
Hip and valley rafters are used where roof planes meet at an angle. Unlike a common rafter, which runs perpendicular to the ridge in a simple gable roof, a hip or valley rafter follows a diagonal path in the roof plan. This additional horizontal distance changes the total rafter length.
Hip and valley rafters run diagonally in plan
GeometryIn plan, the hip or valley follows the diagonal of the roof. Its horizontal run is therefore longer than the common rafter run measured square to the ridge, which is why a separate factor is needed.
Hip and Valley Factor Formula
For a regular 45-degree plan-direction hip or valley:
When the roof pitch is expressed as rise per 12 inches of run:
Example: 6/12 Roof
Hip/Valley Factor = √((6 ÷ 12)² + 2) = √2.25 = 1.500
If the measured horizontal plan run of the hip rafter is 10 feet:
The theoretical hip rafter length is 15 feet, before accounting for overhangs and framing details.
Common Rafter vs. Hip/Valley Rafter
| Roof Pitch | Common Rafter Factor | Hip/Valley Factor |
|---|---|---|
| 4/12 | 1.054 | 1.453 |
| 6/12 | 1.118 | 1.500 |
| 8/12 | 1.202 | 1.563 |
| 10/12 | 1.302 | 1.641 |
| 12/12 | 1.414 | 1.732 |
The horizontal run used for a hip or valley calculation must be measured in the roof plan direction. Do not automatically use the common rafter’s horizontal run.
For a single rafter, the hip rafter calculator applies this factor, and the roof valley calculator covers the valley side of the same geometry.
Rafter Sizing: Why Roof Pitch Is Not Enough
Roof pitch is one factor in roof framing, but it cannot determine the required rafter size by itself. Rafter sizing also depends on:
- Horizontal span and support conditions.
- Lumber species and grade.
- Lumber dimensions.
- Rafter spacing.
- Dead and live loads.
- Snow and wind conditions.
- Applicable building codes.
A roof with a 6/12 pitch does not automatically require a particular lumber size. Two roofs with the same pitch can require different framing because their spans and loading conditions are different.
Use applicable span tables and local building requirements, or have the framing design checked by a qualified professional.
Roof Pitch and Weather Considerations
Roof slope influences how water moves across a roof surface, but pitch alone does not determine weather performance. Other important factors include roofing material, drainage design, flashing, roof penetrations, underlayment, local rainfall, snow loads, and wind exposure.
Rain and Drainage
A steeper roof generally provides a faster drainage path, but proper drainage also depends on valleys, gutters, flashing, roof shape, and installation quality.
Snow and Ice
Snow performance depends on structural design, local snow loads, roof geometry, surface materials, and temperature conditions. A steep roof should not automatically be assumed safe under every snow condition.
Wind Exposure
Wind performance depends on the roof shape, building location, roof covering, fastening system, connections, and applicable design wind loads. Roof pitch alone is not enough to determine wind resistance.
Roof Pitch by Architectural Style
Different architectural designs use different roof profiles. The following are general examples, not mandatory pitch specifications.
| Architectural Style | Common Roof Form | Pitch Characteristics |
|---|---|---|
| Ranch | Low-profile gable or hip | Often uses relatively shallow slopes |
| Craftsman | Gable or intersecting roof | Commonly uses moderate slopes and wide eaves |
| Colonial | Symmetrical gable | Often features steeper roof profiles |
| Tudor | Multiple steep roof sections | Frequently uses pronounced roof slopes |
| A-frame | Continuous steep roof planes | Roof surfaces extend toward the base of the building |
| Gambrel | Two slopes on each side | Combines a steep lower section with a shallower upper section |
| Mansard | Double-slope roof on multiple sides | Uses steep lower sections and a low-slope upper section |
| Modern | Flat or low-slope roof | Often uses membrane roofing and planned drainage |
The appropriate pitch for a building depends on its design, structural requirements, roofing products, climate, and local building regulations.
How to Determine Roof Pitch
Roof pitch can be calculated when the vertical rise and horizontal run are known. For an existing building, measurements should be obtained without attempting to climb onto an unsafe roof. A qualified roofing professional can inspect and measure an existing roof when direct access is required.
Rise, run and roof angle
GeometryRoof pitch is the ratio of rise to run. The angle is the arctangent of that ratio, and the rafter length is the hypotenuse of the same triangle.
Method 1: Use Known Rise and Run
If the vertical rise and horizontal run are already known, use:
For standard roof-pitch notation, express the result as rise over 12 inches of horizontal run.
Example: rise = 6 inches, run = 12 inches, so roof pitch = 6/12.
Method 2: Calculate from Building Dimensions
For a simple symmetrical gable roof, the horizontal run is half the building span, measured from the outside wall line to the ridge’s vertical projection.
Example: building span = 28 feet, half-span = 14 feet, ridge rise above the relevant wall reference = 7 feet.
This method assumes a simple symmetrical gable geometry and correctly measured reference points.
Method 3: Convert an Angle into Roof Pitch
If the roof angle is known in degrees, the rise can be calculated using the tangent function.
Example: angle = 26.57°, so 12 × tan(26.57°) ≈ 6, giving a roof pitch of about 6/12.
If you have an angle and need the pitch, the roof angle calculator performs the conversion directly.
Roof Pitch Conversion Formulas
The following formulas can convert roof pitch into other useful measurements. Rise is the vertical roof measurement, run is the horizontal roof measurement, and angle is the roof angle in degrees.
| Measurement | Formula |
|---|---|
| Roof angle | Angle = arctan(Rise ÷ Run) × 180 ÷ π |
| Slope percentage | Slope (%) = (Rise ÷ Run) × 100 |
| Pitch factor | Pitch Factor = √(1 + (Rise ÷ Run)²) |
| Common rafter length | Common Rafter Length = Horizontal Run × Pitch Factor |
| Hip and valley factor | Hip/Valley Factor = √((Rise ÷ Run)² + 2) |
| Sloped roof area | Sloped Area = Horizontal Plan Area × Pitch Factor |
These formulas describe idealized roof geometry. Complex roofs require separate calculations for each roof plane.
The roof pitch calculator applies these relationships to any rise and run, and the pitch multiplier calculator handles the factor on its own.
Common Roof Pitches Explained
What each pitch means in practice, and what it changes about the roof you are looking at.
2/12 Roof Pitch
The shallow end of what is still usually called a pitched roof.
A 2:12 roof climbs 2 units for every 12 units it travels horizontally. That is a rise of about 1 in 6, an angle of 9.46° and a slope of 16.67%.
At this angle water leaves the roof slowly, so the layers underneath the covering do most of the waterproofing. Laps have to be generous, fasteners have to be right, and any penetration is a place to be careful. Because the pitch factor is only 1.014, the sloped surface is barely 1.4% larger than the flat footprint — area is not the problem here; detailing is.
Not every covering can be installed this shallow. The minimum slope for a specific product comes from that product’s published installation instructions, not from a general rule, so check the data sheet before choosing.
3/12 Roof Pitch
A shallow roof that still sheds water on its own.
A 3:12 pitch rises 3 units per 12 of run: 14.04°, a 25% slope, and a pitch factor of 1.031. It shows up on porches, lean-tos, outbuildings and the lower slopes of some two-storey designs.
Compared with 2:12 it drains noticeably faster, but it is still in the range where laps, underlayment and flashing carry a lot of the load. The area penalty stays small: every 100 sq ft of footprint carries about 103 sq ft of roof surface.
The practical difference between 2:12 and 3:12 is mostly about what you are allowed to install and how carefully the details are built, not about the geometry.
4/12 Roof Pitch
A moderate pitch, and a common dividing line for coverings.
4:12 is 18.43° with a 33.33% slope and a pitch factor of 1.054. It sits near the shallow end of what many roof coverings are rated for, though the exact cut-off is product-specific.
The geometry is forgiving: a 1,000 sq ft footprint carries roughly 1,054 sq ft of surface, so the difference between plan area and roof area is only about 5%. That makes 4:12 a pitch where estimating from a plan drawing stays reasonably accurate.
On a 4:12 roof, walking is usually possible but the surface is still shallow enough that a slip is easy to misjudge. Fall protection requirements depend on your jurisdiction and your employer, not on the pitch alone.
6/12 Roof Pitch
The middle of the range, and the pitch most examples are built on.
6:12 is 26.57°, a 50% slope, with a pitch factor of 1.118. Every 12 units of horizontal run gains 6 units of height, so the rise is exactly half the run.
That 1.118 factor is why a 1,200 sq ft footprint carries about 1,342 sq ft of sloped surface — roughly 12% more material than the plan area suggests. On larger roofs that difference is the gap between a right order and a short one.
6:12 is steep enough to shed water quickly and shallow enough to remain practical to work on. It is the pitch used in the worked examples on the roof pitch calculator, so the numbers here and there match.
8/12 Roof Pitch
A steep roof with meaningfully more surface than its footprint.
8:12 is 33.69° with a 66.67% slope and a pitch factor of 1.202. For every 100 sq ft of footprint you get about 120 sq ft of roof.
That 20% uplift matters for material ordering, for scaffold and roof-jack planning, and for anyone estimating labour. Steep roofs are slower to work on, and the surface area is genuinely larger, not just harder to reach.
Water and debris clear quickly at this angle, which is one reason steep pitches appear in snow-heavy and high-rainfall regions. The trade-off is more surface, more material and more fall-protection planning.
12/12 Roof Pitch
Equal rise and run: 45 degrees exactly.
12:12 is the one pitch where the arithmetic is trivial: rise equals run, so the angle is exactly 45°, the slope is 100%, and the pitch factor is √2 ≈ 1.414.
A roof at this pitch has about 41% more surface than its footprint. A 1,000 sq ft plan area becomes roughly 1,414 sq ft of roof, which is a large enough difference to change an order.
You see 12:12 on A-frames, steep feature gables and some traditional European and North American styles. It is not a working surface for most people: at 45° the roof is well beyond safe walking, and roof jacks, staging or rope access are normal.
Each of the common pitches has its own worked guide: 2/12 roof slope, 3/12 roof slope, 4/12 roof slope, 6/12 roof slope, 8/12 roof pitch and 12/12 pitch roof. Each page carries the rafter length, ridge height and area factor for that slope.
Frequently Asked Questions About Roof Pitch
There is no single roof pitch used for every region or building type. Residential roof designs use different slopes depending on architectural style, climate, roofing materials, and structural requirements.
A 6/12 roof pitch means the roof rises 6 inches vertically for every 12 inches of horizontal run. Its angle is approximately 26.57 degrees.
A 4/12 roof pitch has an angle of approximately 18.43 degrees and a slope percentage of 33.33%.
A 12/12 roof pitch has an angle of exactly 45 degrees because the vertical rise and horizontal run are equal.
Roof pitch and roof slope are often used to describe the same rise-over-run relationship in everyday roofing discussions. However, terminology can vary between technical references. This guide uses ratios such as 6/12 to represent 6 units of vertical rise for every 12 units of horizontal run.
Divide the vertical rise by the horizontal run. To express the result in standard roof-pitch notation, calculate the rise over a 12-inch horizontal run.
Use the inverse tangent of the rise divided by the run, then convert the result to degrees: Angle = arctan(Rise ÷ Run) × 180 ÷ π.
For a simple roof with a consistent slope, multiply its horizontal plan area by the pitch factor: Sloped Area = Plan Area × Pitch Factor.
A pitch factor is a multiplier used to convert horizontal measurements into sloped measurements. It is commonly used to estimate roof surface area and common rafter length.
It is a multiplier used to estimate the length of a hip or valley rafter from its horizontal plan run for a regular 45-degree plan-direction layout.
No. Rafter size also depends on span, lumber species, grade, spacing, loads, support conditions, and local building requirements.
ARMA states that asphalt shingles may be used on slopes from 2:12 to less than 4:12 when special installation procedures are followed. It advises against installing them below 2:12. Always check the exact product instructions and applicable local code.
Under OSHA’s construction regulations, a steep roof has a slope greater than 4:12. A roof with a slope of 4:12 or less is classified as low-slope. Fall-protection requirements also depend on the work conditions and applicable regulation.
For the same horizontal footprint and a simple roof shape, a steeper roof generally has more sloped surface area. Actual material quantities also depend on roof complexity, product coverage, installation patterns, and waste.
The chart provides reference values for a consistent roof slope. Complex roofs with multiple planes, hips, valleys, dormers, and different pitches need separate measurements and calculations.
Free Roofing Calculators
Use the RoofMathLab calculators to apply these roof-pitch measurements to practical roofing calculations.
Technical References
The following references provide additional information about roof pitch, roofing materials, and construction requirements.
- Occupational Safety and Health Administration (OSHA) — 29 CFR 1926.500: Definitions of Low-Slope and Steep Roofs
- Occupational Safety and Health Administration (OSHA) — 29 CFR 1926.501: Duty to Have Fall Protection
- Asphalt Roofing Manufacturers Association (ARMA) — Installation of Asphalt Shingles on Lower Sloped Roofs
- International Code Council (ICC) — 2024 International Residential Code: Roof Assemblies
Always consult the applicable local building code and the roofing product manufacturer’s current installation instructions before making construction decisions.
Calculate Roof Measurements with RoofMathLab
Understanding roof pitch helps make roof measurements and estimates easier to interpret. Use the free calculators to work out roof pitch, convert angles, estimate sloped roof area, and find theoretical rafter lengths for your project.