Roof Pitch Factor Table

The pitch factor for every pitch from 1:12 to 16:12, with the area increase, slope, angle and rafter length per 12 of run.

Quick answer: at 6:12 the factor is 1.1180, the roof surface is 11.8% larger than the footprint, and a rafter rises 13.416 units for every 12 of run.

  • 16 pitches tabulated
  • Area increase included
  • Lookup by pitch

Pitch factor lookup and plan area conversion

Common pitches

Any pitch between 0.25 and 24 works; the reference table below covers whole numbers from 1 to 16.

Enter a footprint to see the sloped area it produces. Leave it blank to use the factor alone.

run rise overhang section through the roof
Rise is vertical, run is level, overhang is measured out from the wall.
Pitch factor
1.1180
at 6:12 · 11.8% more surface
Roof area
1,342 sq ft
Extra surface
142 sq ft
Rafter per 12
13.416
Roof angle
26.57°
Slope
50.00%
Roofing squares
—

The factor converts plan measurements into sloped ones; waste for offcuts is a separate allowance.

Area increase is how much bigger the roof is than the footprint at that pitch. Rafter per 12 is the length needed for every 12 in of horizontal run.

Show calculation

Roof pitch factor table

Every whole pitch from 1:12 to 16:12, computed from the exact ratio. Type a pitch in the box below to highlight that row, or set the calculator above and it follows along.

Pitch factor, area increase, slope, angle and rafter length per 12 of horizontal run.
PitchFactorArea increaseSlopeAngleRafter per 12
1:121.0030.3%8.33%4.76°12.04
2:121.0141.4%16.67%9.46°12.17
3:121.0313.1%25.00%14.04°12.37
4:121.0545.4%33.33%18.43°12.65
5:121.0838.3%41.67%22.62°13.00
6:121.11811.8%50.00%26.57°13.42
7:121.15815.8%58.33%30.26°13.89
8:121.20220.2%66.67%33.69°14.42
9:121.25025.0%75.00%36.87°15.00
10:121.30230.2%83.33%39.81°15.62
11:121.35735.7%91.67%42.51°16.28
12:121.41441.4%100.00%45.00°16.97
13:121.47447.4%108.33%47.29°17.69
14:121.53753.7%116.67%49.40°18.44
15:121.60160.1%125.00%51.34°19.21
16:121.66766.7%133.33%53.13°20.00

Area increase is (factor − 1) × 100. Rafter per 12 is 12 × factor. If you are working from an angle rather than a pitch, the roof pitch chart sets the same values beside the degree and slope columns.

What the roof pitch factor does

A roof plane is a rectangle that has been tilted. One dimension — the one running along the ridge — is unchanged. The other now follows the slope, so it is longer than the horizontal distance it covers.

The pitch factor is exactly how much longer. Multiply the plan dimension by it and you have the sloped dimension; multiply plan area by it and you have roof area.

All of that assumes you already know the pitch. If you have a measured rise and run but not the ratio, the roof pitch calculator converts them first — everything on this page depends on that number being right.

A long timber rafter supported on sawhorses with a tape measure stretched along its length.
The rafter is the sloped length of the plane. Its length relative to the run is the pitch factor.
Apply it to plan measurements, never to sloped ones. Multiplying a dimension you already measured along the roof double-counts the slope.
What the seven figures on the result panel mean.
FigureUnitWhat it isHow to use it
Pitch factorratioSloped length ÷ plan length at that pitchMultiply any plan dimension by it
Roof areasq ft or m²Plan area × factorThe quantity to order against
Extra surfacesq ft or m²Roof area minus plan areaThe area the pitch adds, before any waste
Rafter per 12ratioLength of rafter per 12 of run, equal to 12 × factorScale it by run ÷ 12 for a real rafter length
Roof angledegreesatan(pitch ÷ 12)Setting out, or checking against a drawing
SlopepercentPitch ÷ 12 × 100For drainage notes and flat-roof specifications
Roofing squaressquaresRoof area ÷ 100Ordering: one square covers 100 sq ft of roof

What each pitch factor input and result means

One input, seven results, and an optional area.

The inputs and results.
FigureWhat it meansWhere it comes from
Roof pitchRise per 12 of run — the only thing the factor depends onA level and a tape, or the pitch calculator
Plan areaAn optional footprint to convertYour measurement
Pitch factorSloped length divided by plan lengthThe table, or calculated
Extra surfaceThe area the pitch adds, in square feet and per centPlan area × (factor − 1)
Rafter per 12Length of rafter needed for every 12 in of run12 × factor
Roof areaThe sloped area, once a plan area is enteredPlan area × factor
Roof angleThe pitch in degrees, for saw settings and levelsatan(pitch ÷ 12)
SlopeThe same pitch as a percentage, which is how membranes and drainage tables state limitsPitch ÷ 12 × 100
Roofing squaresThe roof area in squares of 100 sq ft, which is how covering is orderedRoof area ÷ 100

The factor is a property of pitch alone, which is why it can be tabulated once and applied to any measurement. Nothing else — span, area, covering — changes it.

How to use the pitch factor table

A lookup for the multiplier that converts plan measurements into sloped ones.

  1. Find your pitch. Locate the row for your rise per 12 of run.
  2. Read the factor. The pitch factor is the multiplier; the area increase is what it adds as a percentage.
  3. Apply it. Multiply a plan area by the factor for sloped area, or a plan length for slope length.

Roof pitch factor formula

ratio = pitch ÷ 12
factor = √(1 + ratio²)
roof area = plan area × factor
rafter per 12 = 12 × factor
slope (%) = ratio × 100
roofing squares = roof area ÷ 100

Units. The factor is dimensionless, so it works on feet, metres or anything else without conversion. Only the area figures inherit a unit, and they inherit whichever one the plan area was entered in.

The factor

Formula. Ratio = pitch ÷ 12. Factor = √(1 + ratio²). Roof area = plan area × factor. Rafter per 12 = 12 × factor.

Variables. Pitch as rise per 12, ratio dimensionless, factor dimensionless and always 1 or greater. Plan area in square feet or square metres; the roof area comes back in the same unit.

Calculation logic. The expression under the root is Pythagoras: a run of 1 and a rise of the ratio give a hypotenuse of √(1 + ratio²). Because the factor is expressed per unit of run, it scales any measurement directly — there is no separate version for lengths and areas, because only one dimension of a tilted plane changes.

Example. At 8:12 the ratio is 0.6667, so √(1 + 0.4444) = 1.2019. A 1,000 sq ft plan becomes 1,201.9 sq ft of roof.

Result interpretation. The factor is a property of the pitch alone. Two roofs at the same pitch share it regardless of size, shape or covering, which is why it can be tabulated once and used everywhere. Applying it is the pitch multiplier calculator's job if you would rather enter a measurement than read a table.

How to use the pitch factor table for area

  1. Find your pitch in the first column. For a pitch between whole numbers, use the lookup above.
  2. Multiply plan length by the factor to get the sloped length of that plane.
  3. Multiply plan area by the factor to get roof area.
  4. Use rafter per 12 as a scale figure: multiply by your run divided by 12.

For a 15 ft run at 6:12, the rafter length is 13.416 × (15 ÷ 12) = 16.77 ft, before any overhang or ridge deduction.

If you are starting from a measured rise and run rather than a pitch, the rise and run calculator produces the ratio this table is indexed by.

And once you have roof area, dividing by 100 gives squares, which is where the roofing square calculator begins.

A tape measure laid along a shingled roof slope to measure the length of the plane.
Measuring along the slope gives the surface directly. The factor is only needed when you are starting from a plan dimension.

Roof pitch factor table limitations

  • Geometry only. The factor says nothing about whether a pitch suits a covering — the minimum roof pitch calculator checks that.
  • One pitch per plane. A roof with mixed pitches needs a factor for each.
  • No waste. Offcuts, hips and valleys are a separate allowance.
  • No overhang. Add overhangs to the plan measurement before multiplying.
  • A factor is a ratio, not a quantity. Multiplying an area by it gives another area. It carries no allowance for waste, laps or the coverage of a product, and applying it to a figure that already includes those double-counts them.
  • One factor per plane. A roof with two pitches needs each plane converted separately, and a single factor applied across both is wrong on each side.
  • The table is a lookup, not a survey. It gives the factor for a pitch you have established elsewhere. If the pitch itself is uncertain, the factor inherits that uncertainty.
  • Rounded factors accumulate. Using 1.12 instead of 1.118 on a large roof moves the answer by a fifth of a percent, which is fine for a budget and not fine for an order.

Roof Pitch Resources and Guides

Reference values for the pitches you are most likely to be converting.

Frequently asked questions

It is the number you multiply a horizontal measurement by to get the length along the slope. At 6:12 the factor is 1.118, so 12 ft of plan becomes 13.42 ft along the rafter. Because a tilted plane only gets longer in one direction, the same factor converts plan area into roof area.

Because the sloped path is the hypotenuse of a right triangle and the horizontal is one of its legs. The hypotenuse is always the longest side. At a dead-flat roof the factor is exactly 1, and it rises as the pitch steepens.

Divide the pitch by 12 to get the ratio, square it, add one, and take the square root. At 8:12 the ratio is 0.6667, so the factor is √(1 + 0.4444) = 1.2019. It is also equal to 1 divided by the cosine of the roof angle, which is a useful cross-check.

It is how much larger the roof surface is than the footprint, as a percentage. A 6:12 roof has about 11.8% more surface than the area it covers. That increase is geometry, not waste. Waste for offcuts is a separate allowance added on top.

It is the length of a rafter whose horizontal run is exactly 12 units, and it equals 12 times the factor. At 6:12 it is 13.416. To get a real rafter length, scale it: for a 15 ft run, multiply 13.416 by 15 ÷ 12.

No, and they are applied at different steps. The pitch factor corrects for slope and is fixed by geometry. Waste covers offcuts and breakage and depends on the roof's complexity and the product. Multiplying by both is correct; using one as a substitute for the other is not.

1.4142, which is √2. At 12:12 the rise equals the run, so the roof angle is 45° and the surface is about 41.4% larger than the footprint.

Yes, for the sloped length from the wall line to the ridge. Add any overhang to the horizontal run before multiplying, and deduct half the ridge thickness if the rafter bears on the side face of the ridge. The rafter calculator handles those adjustments.

Rounding. A table computed from a rounded pitch or a rounded ratio will drift slightly from one computed from exact values. The values here are computed from the exact ratio and rounded only for display.

1.1180. Six inches of rise per foot of run is a slope of 0.5, so the factor is the square root of 1.25, which is 1.11803. It means a 6:12 roof has 11.8% more surface than its footprint — 1,000 sq ft of plan becomes 1,118 sq ft of roof. It is the most useful single figure to memorise, because 6:12 is the most common residential pitch.

Measure the plan area — the footprint, including overhangs — and multiply it by the factor for that pitch. A 40 × 30 ft footprint with 1 ft overhangs all round is 42 × 32 = 1,344 sq ft of plan; at 6:12 that becomes 1,344 × 1.1180 = 1,503 sq ft of roof. Two cautions: the plan must include the overhangs, and the measurement must be horizontal. A tape laid on the slope is already the surface, and multiplying it by the factor applies the pitch twice.

Yes, and it is the same number. A rafter is the hypotenuse of the same triangle whose sides are the rise and the run, so the slope length is the run multiplied by the factor — exactly as the roof area is the plan area multiplied by it. A 12 ft run at 6:12 gives a rafter of 12 × 1.1180 = 13.42 ft, before any allowance for the overhang or the birdsmouth. The one difference is that a rafter needs the overhang added to the run first, then the factor applied.

Where these numbers come from

Every value in the table is computed from the pitch ratio using Pythagoras. There is no empirical input, so the table cannot drift from the formula.

  • Pythagorean relationship for a right triangle with a unit run.
  • Trigonometric identity: the factor equals the secant of the roof angle.

Displayed values are rounded to four decimals; the lookup keeps full precision.

Before you apply it

Four checks before the factor goes into a takeoff.

  • Apply it to plan dimensions. Anything already measured along the slope carries the factor, and applying it again double-counts.
  • Interpolate with care. The factor is not linear in pitch, so between two rows calculate it rather than averaging the values.
  • One factor per pitch. A roof with two pitches needs two lookups, not one compromise figure.
  • Keep the rounding to the end. Four decimals is display precision, not site precision, and the table is a lookup rather than a measurement.

Every value in the table is the same square root evaluated at a different ratio, so a disagreement between two rows means an arithmetic slip rather than a data problem.

Need to apply it to a measurement?

The factor is only half the job — the other half is multiplying a real plan dimension by it.

Scroll to Top