Skylight Natural Light Calculator

How much daylight a skylight delivers is set by three things: how much glass there is against the floor area, how much light the glazing lets through, and how much sky it can see. The skylight natural light calculator turns those into a daylight factor, and back into the glass area a target needs.

Quick answer: 20 sq ft of glazing in a 300 sq ft room is a 6.7% glazing ratio. At 0.60 visible transmittance and a 0.50 sky factor that is a daylight factor of 2.00% — the bottom of the range that counts as adequately lit.

  • Daylight factor in percent
  • Glazing area for a target
  • A planning estimate

Inputs and results

Transmittance is the visible transmittance on the product label. The sky factor is a judgement: about 0.5 for a roof window that sees open sky, lower where a well or a neighbouring roof cuts it down.

Opening on the roof planeopening widthcurb heightroof plane
Measure the opening width and the curb height at the opening itself. → daylight factor
Daylight factor (%)
2.00
Glazing ratio (%)
6.7
Glazing for target (sq ft)
20.0

The daylight factor is the indoor light level as a percentage of the outdoor level. The last figure is the glass area that would reach your target in the same room.

Show calculation

What the skylight natural light calculator works out

Daylight factor is the light inside a room as a percentage of the light outside it, under a standard overcast sky. It is the number daylight design is argued in, and the skylight natural light calculator estimates it from the glazing ratio, the transmittance of the glass and how much sky the opening can see.

It also runs the other way: give it a target and it returns the glass area that would reach it in the same room. That is the skylight sizing question in its simplest form, and it is usually the one being asked.

The estimate is proportional, not a simulation. A real daylight factor depends on the room's surfaces, the depth of the well and the position of the point being measured, and the skylight well depth calculation is where the shaft is dealt with.

Two roof windows in a vaulted ceiling above a living room, with daylight pooling on the walls and floor.
Roof windows put light where a wall window cannot reach.

The five inputs and three results

Two fields describe the room and the opening, two describe the glass and the sky, and one sets the target.

InputUnitWhat it isHow to obtain it
Skylight glazing areasq ftThe glass, not the openingThe product size, or measured on the glass
Room floor areasq ftThe floor the light lands onMeasured, or from the plan
Glazing transmittance0–1Share of visible light the glass passesThe visible transmittance on the NFRC label
Sky factor0–1How much sky the opening seesA judgement: about 0.5 for an open roof window
Target daylight factor%The performance you are aiming for2% for ordinary rooms, 3 to 5% for task areas

All five are entered on the left of the calculator, and the result updates as you type.

The three results

One is the performance, one is the quantity, and one is the design answer.

ResultUnitWhat it means
Daylight factor%Indoor light as a percentage of the outdoor level.
Glazing ratio%Glazing area as a percentage of floor area.
Glazing for targetsq ftThe glass area that would reach the target in this room.

The last figure is the one to take to a product schedule: it converts a daylight target into an area to buy.

Choosing the transmittance and the sky factor

Two of the five fields are judgement rather than measurement, and they are where the estimate can be wrong by a third.

The glazing area

Use the glass, not the rough opening. A skylight with a wide frame can have a quarter less glass than its nominal size, and it is the glass that lets the light through.

Where there are several units, add their glass areas. Two 10 sq ft skylights and one 20 sq ft skylight give the same daylight factor, though not the same distribution.

The transmittance

Visible transmittance is on the NFRC label alongside the U-factor, and it runs from 0 to 1. Clear double glazing is around 0.7, a low-e coating brings it to 0.5 to 0.6, and a heavily coated or tinted unit can fall below 0.4.

It is a different number from the U-factor and the solar heat gain coefficient, and choosing a product on one of them can compromise the others. The skylight energy calculation is where the heat side is priced.

The sky factor

This is the share of an unobstructed sky hemisphere that the opening actually sees. A roof window facing open sky is around 0.5 to 0.6; one at the bottom of a deep well, or with a neighbouring roof close by, is lower.

The figure is a judgement and it is worth being honest about it: a well two feet deep can take a third off the light before the glazing is considered, which is what the well depth calculation quantifies.

The target

Two per cent is the usual threshold for a room that is adequately daylit; below it, artificial light is needed most of the day. Five per cent and above is brightly lit, and glare and summer heat become the problem rather than the lack of light.

For a kitchen, a stair or a room used for close work, aim at 3 to 5%. For a circulation space, 1 to 2% is plenty.

Common measuring mistakes

  • Opening size used as glazing area. Overstates the light by the width of the frame.
  • U-factor entered as transmittance. They are different properties on the same label.
  • Sky factor left at 1. No roof window sees the whole sky hemisphere.
  • Floor area of the whole house used. The factor applies to the room the light lands in.
  • The daylight factor read as a guarantee. It is an average, not a map of brightness.

How to use the skylight natural light calculator

Five fields, and the sky factor is the one to think about rather than look up.

  1. Enter the glazing area. The glass, summed over the units.
  2. Enter the room floor area. The room the light lands in.
  3. Enter the transmittance. From the product label.
  4. Enter the sky factor. About 0.5 for an open roof window, less for a deep well.
  5. Enter the target. 2% for an ordinary room, more for task lighting.

Then read the last result: if it is larger than the glazing you have, the room is under-lit, and the difference is the extra glass the target needs.

The arithmetic: glazing ratio and daylight factor

glazing ratio = glazing area ÷ floor area × 100
daylight factor = glazing ratio × transmittance × sky factor
glazing for target = target × floor area ÷ (transmittance × sky factor × 100)

Variables

glazing area
The glass, in square feet.
floor area
The room's floor, in square feet.
transmittance
Visible transmittance of the glazing, from 0 to 1.
sky factor
The share of the sky hemisphere the opening sees, from 0 to 1.
target
The daylight factor being aimed at, in per cent.

Unit explanation

The glazing ratio is an area over an area, so it is dimensionless until it is multiplied by 100 to read as a percentage. The daylight factor is that percentage multiplied by two fractions, so it stays a percentage.

Rearranging for the target divides the daylight factor by the same two fractions, which is why the third formula looks like the second run backwards.

Why a proportional model

A rigorous daylight factor integrates the sky visible from every point in the room, then adds the light bounced off the walls and the ground. That is a simulation, and it needs the room's geometry and finishes.

This page assumes the light reaching the floor is proportional to the glass area, discounted by what the glass passes and how much sky it sees. That holds well enough to size an opening and badly enough that a detailed design should be modelled.

Why the sky factor matters so much

It is the term that captures the well, the neighbouring roof and the orientation. Two identical skylights, one at the top of a shallow shaft and one at the bottom of a deep one, differ by more in this factor than a change of glazing would recover.

That is why the well is worth detailing: the cheapest way to raise a daylight factor is often to shorten or splay the shaft rather than to add glass.

Numerical example

20 sq ft of glass in a 300 sq ft room, transmittance 0.60, sky factor 0.50, target 2%:

Glazing ratio
20 ÷ 300 × 100 = 6.7%
Daylight factor
6.7 × 0.60 × 0.50 = 2.00%
Glazing for 2%
2 × 300 ÷ (0.60 × 0.50 × 100) = 20.0 sq ft

The two answers agree, which is the check that the rearrangement is right. Raise the target to 3% and the glass area needed rises to 30 sq ft in the same room.

Result interpretation

The daylight factor is an average for the room, not a measure of the brightest or the darkest point. A room at 2% can still have a bright pool under the skylight and a dim corner behind a beam.

Read against the bands: under 2% is under-lit for most of the day, 2 to 5% is comfortably daylit, and above 5% the risk shifts from darkness to glare and summer heat gain.

Worked examples: a small room and a larger one

Example 1 — one skylight in a small room

Inputs: 20 sq ft of glass, 300 sq ft floor, transmittance 0.60, sky factor 0.50, target 2%.

Glazing ratio
6.7%
Daylight factor
2.00%
Glazing for target
20.0 sq ft

Adequate, and only just. The room sits at the bottom of the comfortably daylit band, so a slightly smaller unit or a deeper well would drop it below 2% and into the range where the lights go on at midday.

6.7 × 0.60 × 0.50 = 2.00%

Example 2 — a bigger room with a weaker sky

Inputs: 30 sq ft of glass, 400 sq ft floor, transmittance 0.50, sky factor 0.45, target 2%.

Glazing ratio
7.5%
Daylight factor
1.69%
Glazing for target
35.6 sq ft

More glass and a higher glazing ratio, and still under target, because the coated glazing passes less light and the well takes more of the sky. Reaching 2% needs another 5.6 sq ft of glass — or a shorter well.

7.5 × 0.50 × 0.45 = 1.69%

What the daylight factor leaves out

The estimate is an average, and four things decide whether the room feels like the number says.

Room surfaces

Light bounced off walls, ceiling and floor is a real part of the daylight factor, and dark surfaces absorb it. A room with pale finishes reads brighter than the same geometry in dark ones, and the proportional model does not see it.

Where the room is being redecorated at the same time as the skylight is fitted, the finish is a free improvement to the daylight factor.

The well

A shaft between the roof and the ceiling cuts the sky the opening sees, and it shades the light once it is in. A deep, narrow well with dark sides can halve the useful light from an otherwise generous skylight.

Splaying the well outward, and keeping its sides pale, is the standard fix and it costs nothing at the design stage.

Glare and uniformity

A skylight is a bright source in the upper field of view, and a small one directly overhead can cause glare out of proportion to the light it delivers. Two smaller units spread apart are usually better than one large one in the same total area.

Uniformity is not in the daylight factor at all: the average can be 2% with a bright pool and a dark corner behind it.

Tubular skylights

A tube is a long well by another name. It delivers useful light for a small roof penetration, and its performance is dominated by the same factors: the length of the tube, its reflectivity and how much sky the dome sees.

The skylight tunnel calculation is where a tube is sized, and the daylight factor here applies to it with a lower sky factor.

The other half of the decision

A skylight also loses heat in winter and gains it in summer. The skylight energy calculation prices that side, and the two together are the whole case for or against the opening.

Glazing area is only half of the comparison. The roof-to-floor ratio estimator gives the roof area the skylights sit in, which is often the missing figure when a daylight target is set from the floor plan alone.

Looking up a deep white light well to a bright square skylight at the top.
A well takes light out of the opening before the room ever sees it.

Limitations and assumptions

What the calculation assumes

  • A proportional model. Light is assumed to scale with glass area, discounted by transmittance and sky factor.
  • An overcast sky. Daylight factor is defined under a standard overcast sky, not a sunny one.
  • An average for the room. The result is a single figure, not a distribution across the floor.
  • One room, one opening group. Open-plan spaces with several openings are treated as one volume.
  • A judgement for the sky factor. The value entered is the largest source of error.

What it does not include

  • Room reflectance. Dark surfaces reduce the real daylight factor.
  • Well depth and splay. Captured only through the sky factor.
  • Glare. Not modelled, and it is why a small bright opening can disappoint.
  • Sun. Direct sun is a different calculation with a different comfort question.
  • Heat. The energy side is a separate page.

The result is a planning estimate of the average daylight factor. It sizes an opening sensibly and it does not replace a daylight model on a project where the lighting is critical.

How the numbers behave

The daylight factor is the glazing ratio multiplied by two fractions, so it rises in a straight line with the glass and falls in a straight line with the coatings.

Glazing ratioDaylight factorBand
2%0.60%Under-lit
4%1.20%Under-lit
6.7%2.00%Adequately lit
10%3.00%Well lit
15%4.50%Bright, glare likely

Transmittance 0.60, sky factor 0.50. The bands follow the usual guidance that 2% is the threshold and 5% is bright.

Turning it around is more useful at the design stage: pick the target, and the table gives the glass area for a given room.

Target daylight factorGlass for 300 sq ftGlass for 500 sq ftUse
1%10 sq ft16.7 sq ftCirculation
2%20 sq ft33.3 sq ftOrdinary room
3%30 sq ft50.0 sq ftKitchen, stair
5%50 sq ft83.3 sq ftTask lighting

Transmittance 0.60, sky factor 0.50. A lower transmittance or a deeper well scales every figure up in proportion.

Read together, the tables make the trade visible: the glass area needed for a target grows with the floor, and anything that reduces transmittance or sky has to be paid for in more glass.

Frequently asked questions

The light inside a room as a percentage of the light outside, measured under a standard overcast sky. Two per cent is the usual threshold for a room that is adequately daylit; under that, artificial light is needed through most of the day.

For 2% in a 300 sq ft room with clear double glazing, about 20 sq ft of glass — a glazing ratio near 7%. That is the figure the calculator returns in the third result, and it scales with the floor area and inversely with transmittance and sky factor.

The share of visible light the glazing passes, from 0 to 1, and it is on the NFRC label. Clear double glazing is about 0.7; a low-e coating brings it to 0.5 or 0.6. It is not the same as the U-factor or the solar heat gain coefficient, though all three are on the same label.

About 0.5 for a roof window that sees open sky, and less for one at the bottom of a deep well or shaded by a neighbouring roof. It is a judgement rather than a measurement, and it is the largest single source of error in the estimate.

More total light, yes, but not necessarily better light. A single large unit overhead gives a bright pool and glare; two smaller units spread apart give a more even result for the same area. Uniformity is not in the daylight factor, and it is what people notice.

Because it both reduces the sky the opening sees and shades the light on its way down. A deep, narrow, dark shaft can halve the useful light from a generous skylight, and splaying it and keeping the sides pale is cheaper than adding glass.

No. Daylight factor is defined under an overcast sky precisely so that orientation and time of day drop out. Direct sun is a different calculation, and for a skylight it is mostly a question of summer heat and glare rather than of useful light.

No. It is a proportional estimate of the average, without room surfaces, glare or distribution. A project where the lighting is critical needs a proper model, and this page is the check on whether the opening is in the right range before that model is run.

Where these numbers come from

The glazing ratio is glass area over floor area as a percentage, the daylight factor is that percentage discounted by transmittance and sky factor, and the third result rearranges the same relationship for a target.

No transmittance, sky factor or floor area is asserted here, because all three describe a particular room and product.

  • The daylight factor and its bands. Daylight factor defines it as indoor illuminance over outdoor illuminance under a CIE overcast sky, and gives the usual guidance that under 2% is not adequately lit while over 5% is well lit with glare and solar gain becoming the problem.
  • The transmittance. National Fenestration Rating Council certifies visible transmittance on the product label, alongside the U-factor and solar heat gain coefficient.
  • The sky factor. A judgement of how much unobstructed sky the opening sees, around 0.5 for an open roof window and lower behind a well.
  • The target. Two per cent for ordinary rooms, 3 to 5% for task areas, following the same guidance.

Choosing the skylight?

The light and the heat are two calculations on the same opening.

Scroll to Top