Ice Dam Risk Calculator

An ice dam needs snow on the roof, air below freezing, and a deck above freezing. The first two are weather; the third is the building. Enter the temperatures, the snow, the attic R-value and how leaky the ceiling is, and this page returns how much meltwater the eave has to pass and a risk band.

Quick answer: at 70°F inside and 20°F out, 8 in of snow, R-30 and an attic leaking 0.10 BTU/h·ft²·°F, the deck melts 0.21 in of water a day and the dam load is 0.24 — High. Sealing the ceiling to 0.04 drops it to 0.13, Moderate; taking the insulation from R-30 to R-49 only moves it to 0.21.

  • Heat flow, not snow depth
  • Leakage and R side by side
  • Screening band, not a forecast

Inputs and results

Leakage is the field most people have to guess: 0.04 is a sealed, air-barriered ceiling, 0.10 a typical unsealed one, 0.25 a ceiling full of recessed lights and open chases.

width length plan (footprint) pitch section
Both dimensions are measured on plan, not along the slope.
Dam load (in of water per day)
0.24
Meltwater (in/day)
0.21
Risk band
High

Dam load is the meltwater at the deck adjusted for how much snow is sitting on it and how quickly the slope drains.

Show calculation

An ice dam is a heat problem wearing a snow coat

Three things have to be true at once: snow on the roof, outdoor air below freezing, and a deck above freezing. The snow supplies the water, the cold air supplies the refreeze at the eave, and the warm deck supplies the melt. Take any one away and the dam cannot form.

The warm deck is the part a building owner controls, and it is fed by two things: heat conducted through the insulation and heat carried on air leaking out of the house. The second is usually the larger of the two, which is why a ceiling full of recessed lights dams while a sealed one at the same R-value does not.

This page adds both paths into one heat flow, converts it to meltwater at the deck, and adjusts for the snow sitting on the roof and the slope that has to drain it. The result is a band you can compare between roofs, not a prediction for a particular winter.

A thick ice dam along a roof eave with icicles hanging below and snow on the roof above.
The dam forms where meltwater refreezes at the cold eave.

The six inputs and three results

Two fields describe the weather, one the snow, one the slope, and two the ceiling.

InputUnitWhat it isHow to obtain it
Indoor temperature°FThe conditioned space under the ceilingA thermostat, or the design indoor temperature
Outdoor temperature°FA cold winter day, not the coldest on recordThe design winter temperature, or a typical January day
Snow depth on roofinWhat is lying on the roof when the dam formsMeasured with a rule, or the depth after a typical storm
Roof pitchrise per 12Slope of the plane above the ceilingMeasured, or taken from the drawings
Attic insulation R-valueh·ft²·°F/BTUWhat sits between the ceiling and the atticThe insulation specification, or the depth and type
Attic air leakageBTU/h·ft²·°FHeat carried into the attic on leaking airEstimated from the ceiling's penetrations, or from a blower door

All six are entered on the left of the calculator, and the result updates as you type.

The three results

One is the heat's effect at the deck, one is the load at the eave, and one is the band.

ResultUnitWhat it means
Meltwater at the deckin/dayWater melted from the underside of the snow by the heat crossing the ceiling.
Dam loadin/dayThat meltwater adjusted for the snow reservoir above it and the slope's ability to drain it.
Risk band—Low, Moderate, High or Very high, read off the dam load.

The two energy figures are in inches of water per day because that is what the eave has to deal with; a rate in BTU would not compare to anything a roofer can see.

Choosing the temperatures, the snow and the leakage

The two temperatures

Use a cold design day rather than the coldest night on record, because the dam forms over days of steady cold, not in an hour of extreme. For most of the snow belt that is somewhere between 10°F and 25°F.

The indoor figure is the conditioned space, not the attic. A cathedral ceiling with no attic runs hotter at the deck than the room suggests, and a vented attic runs colder, which is why the same house can dam on one side and not the other.

The snow depth

Measure what is lying on the roof, not the depth on the lawn. Wind scours ridges and drifts valleys, so a roof can carry twice the depth at the eave that it carries at the ridge, and the eave is where the dam forms.

Snow is also an insulator at roughly R-1 per inch, so a deep pack warms the deck from above as well as below. The page treats depth as the water reservoir, which is the conservative direction.

The pitch

Pitch is the rise per 12 of run, so a 6:12 roof goes in as 6. Steeper roofs shed snow and drain meltwater before it can refreeze, which is why they dam less often than low-slope roofs in the same climate.

The pitch term is the weakest lever in the calculation, and the behaviour section shows how little it moves the result between 3:12 and 12:12.

The R-value and the leakage

The R-value is the insulation above the ceiling, not the whole assembly. If you know the depth and the type, the roof insulation calculation converts it to an R-value.

Leakage is the field worth spending time on. A sealed, air-barriered ceiling with a continuous top plate is around 0.04; a typical unsealed attic with a hatch and some penetrations is 0.10; a ceiling with recessed lights, a dropped soffit, an open chase or ductwork in the attic is 0.25 or worse. A blower-door test gives the number directly if you have one.

Common measuring mistakes

  • Using the record low. A design day is what the dam sees for a week, not the coldest hour of the decade.
  • Reading snow on the ground. Drifts and scouring make the roof depth a different number.
  • Entering the nominal insulation thickness. Settled loose-fill is thinner than it was installed.
  • Assuming R-value covers leakage. It does not, and on most houses the leakage term is the bigger one.
  • Forgetting the attic ducts. Ducts and air handlers in a vented attic push the leakage term far higher than any insulation upgrade can offset.

How to use the Ice Dam Risk Calculator

Six fields, and the two that change the answer most are the last two.

  1. Enter the indoor temperature. The room below the ceiling, usually 68°F to 72°F.
  2. Enter the outdoor temperature. A cold design day for the location.
  3. Enter the snow depth. On the roof, at the eave where the dam forms.
  4. Enter the pitch. Rise per 12 of the plane above the ceiling.
  5. Enter the R-value. The insulation above the ceiling as it is now.
  6. Estimate the leakage. 0.04 sealed, 0.10 typical, 0.25 leaky, or a blower-door figure.

Then run it twice: once as the attic is, and once with the leakage at 0.04. The gap between the two is what air sealing is worth on this roof, and it is usually larger than the gap between two insulation levels.

How the dam load is worked out

ΔT = indoor − outdoor
UA = 1 ÷ R + leakage
meltwater = ΔT × UA ÷ 31.2
dam load = meltwater × (1 + snow ÷ 12) ÷ (1 + pitch ÷ 12)
bands: <0.05 low, 0.05–0.15 moderate, 0.15–0.30 high, >0.30 very high

Variables

indoor, outdoor
Air temperatures either side of the ceiling, in °F.
R
Insulation resistance above the ceiling, in h·ft²·°F/BTU.
leakage
Heat carried into the attic by leaking air, in BTU/h·ft²·°F of ceiling.
UA
The ceiling's total conductance, conduction plus leakage, per square foot.
snow
Depth on the roof, in inches.
pitch
Rise per 12 of run.
31.2
The conversion from heat flux to inches of water melted per day, explained below.

Unit explanation

ΔT in °F multiplied by UA in BTU/h·ft²·°F leaves a heat flux in BTU/ft²/h. That is the heat arriving at the underside of the deck, per square foot of ceiling.

Melting ice takes 144 BTU per pound, and an inch of water over a square foot weighs 5.2 lb, so an inch of melt needs 749 BTU per square foot. Divided across 24 hours that is 31.2 BTU/ft²/h for one inch of water per day, which is where the constant comes from.

Why leakage is added rather than ignored

Heat reaches the attic two ways: through the insulation and on the air that escapes the house. The first is 1/R per square foot. The second is the leakage term, and on an unsealed ceiling it is typically two to five times larger than 1/R for R-30.

That is the whole reason this page carries a sixth field. An R-30 ceiling leaking at 0.10 has an effective UA of 0.133, which is the same heat flow as a sealed R-7.5 ceiling. Insulating over a leak changes very little; sealing it changes everything.

Why snow and pitch adjust the load

Snow is the water reservoir: the deeper the pack, the longer meltwater is produced and the more of it arrives at the eave before the roof clears. The factor 1 + snow/12 treats a foot of snow as double the load of a bare roof.

Pitch works the other way. A steeper plane drains faster, so meltwater leaves before it can refreeze at the eave, and the factor 1 + pitch/12 discounts the load as the slope rises. Both factors are dimensionless and both are heuristics rather than measured relationships.

Numerical example

70°F inside, 20°F outside, 8 in of snow, 6:12 pitch, R-30 and leakage 0.10:

Temperature difference
70 − 20 = 50°F
Total conductance
1 ÷ 30 + 0.10 = 0.133 BTU/h·ft²·°F
Heat flux
50 × 0.133 = 6.67 BTU/ft²/h
Meltwater
6.67 ÷ 31.2 = 0.21 in/day
Dam load
0.21 × (1 + 8/12) ÷ (1 + 6/12) = 0.24
Band
0.24 falls between 0.15 and 0.30, so High

The same ceiling sealed to 0.04 gives a UA of 0.073, a meltwater rate of 0.12 and a dam load of 0.13 — Moderate. Raising the insulation to R-49 instead gives 0.21, still High.

Result interpretation

The band is a comparison, not a probability. Two roofs scored on the same day can be ranked; one roof scored twice can show what a change is worth. It does not say whether a dam will form this winter, because that depends on the weather sequence as much as the building.

Treat anything at High or above as a roof that needs work on the ceiling before it needs work on the eave. The roof ice barrier width calculation is the second line of defence, not the first.

Worked examples: a modern ceiling and an old one

Example 1 — R-30 with a typical unsealed ceiling

Inputs: 70°F inside, 20°F outside, 8 in of snow, 6:12 pitch, R-30, leakage 0.10.

Temperature difference
50°F
Total conductance
0.133 BTU/h·ft²·°F
Heat flux
6.67 BTU/ft²/h
Meltwater at the deck
0.21 in/day
Dam load
0.24
Band
High

A code-minimum ceiling is not a defence on its own. The insulation is doing its job, but the air moving through the same ceiling is carrying three times the heat the insulation is resisting, and the band reflects that.

50 × 0.133 = 6.67 BTU/ft²/h → 0.21 in/day → load 0.24

Example 2 — an older ceiling, leakier and colder

Inputs: 70°F inside, 10°F outside, 14 in of snow, 4:12 pitch, R-13, leakage 0.25.

Temperature difference
60°F
Total conductance
1 ÷ 13 + 0.25 = 0.327
Heat flux
19.62 BTU/ft²/h
Meltwater at the deck
0.63 in/day
Dam load
1.02
Band
Very high

Three times the meltwater of Example 1, and the load is four times higher because the snow is deeper and the pitch is shallower. This is the roof that has icicles every January, and no amount of eave heating fixes it — the heat is coming from inside.

60 × 0.327 = 19.62 BTU/ft²/h → 0.63 in/day → load 1.02

The fixes, in the order they are worth doing

The calculation has one dominant term and three minor ones. Work down the list in that order rather than starting with the eave.

Air sealing the ceiling

Every hole in the ceiling plane is a chimney: recessed lights, the attic hatch, bath fans, wiring penetrations, the top plate at partitions, and the chase around the flue. Sealing them is cheap, unpleasant work that pays back in the same winter, and it is the only measure that moves the leakage term.

Where the ceiling is being rebuilt, a continuous air barrier is the right answer; where it is not, foam and caulk at every penetration is the practical one.

Insulation

More R helps, but by less than the marketing implies: R-30 to R-49 moves this calculation from 0.24 to 0.21. Insulation only does its job once the air path is closed, which is why the sequence is seal first, insulate second.

Where the insulation is thin because loose-fill has settled, topping it up restores the R-value that was specified rather than adding a new one.

Ventilation

Ventilation flushes heat that still reaches the deck, and it is the third layer rather than the first. The roof vent calculation sizes the free area the roof needs if the assembly is vented at all.

A vented roof still dams if the ceiling leaks, because the air path delivers heat faster than the vents can remove it. Vents also do nothing for the overhang, which is the coldest part of the roof.

The eave and the ice barrier

An ice barrier membrane under the shingles does not stop a dam forming; it stops the water backing up into the deck. Where the code requires it, the width is set by the eave overhang and the climate, which is what the ice barrier width calculation works out.

A snow-covered lower roof with a thick ice dam and icicles along the eave where meltwater has refrozen.
The dam sits at the eave and is fed from above, which is why the barrier goes under the shingles rather than on them.

Insulating over the exterior wall and sealing the top plate keeps the overhang closer to the outdoor temperature, which is the detail that makes the difference between an eave that ices and one that does not.

Removing snow and ice

Taking snow off the roof removes the water supply and is the only measure that works during the storm. It is also the most dangerous, so it is priced and described properly on the roof snow removal cost calculation rather than recommended casually here.

Chips and hammers are a bad idea on any covering. A roof rake from the ground, working from the eave upward, is the safe version.

Heat cable and snow guards

Heat cable opens a channel through the dam so water can escape; it does not remove the heat source and it costs electricity every hour it runs. The ice melt cable calculation sizes it, and it is best treated as a temporary measure while the ceiling is fixed.

Snow guards are about the avalanche, not the dam: they hold the pack on the roof instead of letting it slide onto whatever is below. That is a different problem with a different calculation.

Limitations and assumptions

What the calculation assumes

  • Steady state. The heat flow is treated as constant, so the warming and cooling of the deck through a weather cycle is not modelled.
  • One ceiling, one condition. A ceiling that is sealed in one bay and open in another is reduced to a single leakage figure.
  • Snow as a reservoir. Depth sets how much water is available; its insulating effect, about R-1 per inch, is not applied to the deck temperature.
  • An even eave. The overhang is assumed to be uniformly cold, without a warm wall below it or a sun-facing exposure.
  • Free drainage until it freezes. Meltwater is assumed to run down the slope rather than pond on a low-slope roof.

What it does not include

  • Sun and orientation. A south-facing plane sheds snow and dries its eave; a north-facing one does neither.
  • Attic ducts and equipment. Ducts in a vented attic push the real leakage far above any figure entered here.
  • Roof covering and colour. Metal sheds snow differently from shingle, and a dark surface absorbs more sun.
  • Gutters. A gutter full of ice holds meltwater against the eave, which the calculation does not see.
  • Weather history. A dam is built by a sequence of storms and thaws, not by one design day.

The band is a screening tool for comparing roofs and for showing which change is worth making. It is not a warranty that a roof will or will not dam, and it is not a substitute for looking at the ceiling.

How the numbers behave

Leakage dominates everything else. At the default temperatures, snow and pitch, moving the ceiling from leaky to sealed does more than any realistic change to the insulation.

Attic air leakageTotal UAMeltwaterDam loadBand
0.04, sealed0.0730.12 in/day0.13Moderate
0.10, typical0.1330.21 in/day0.24High
0.15, leaky0.1830.29 in/day0.33Very high
0.25, very leaky0.2830.45 in/day0.50Very high

R-30, 70/20°F, 8 in of snow, 6:12. UA in BTU/h·ft²·°F.

Now the same sweep on insulation, holding the leakage at the typical 0.10. The ceiling goes from R-10 to R-49, a fivefold change in insulation, and the dam load falls from 0.36 to 0.21.

Attic R-valueTotal UAMeltwaterDam loadBand
R-100.2000.32 in/day0.36Very high
R-200.1500.24 in/day0.27High
R-300.1330.21 in/day0.24High
R-400.1250.20 in/day0.22High
R-490.1200.19 in/day0.21High

Leakage 0.10, everything else at the defaults. The last two rows are within a rounding step of each other.

The shape is the point. Adding insulation to a leaking ceiling is like insulating a wall with the window open: the conductive term shrinks, the leakage term does not, and the total barely moves. Sealing first, then insulating, is the only order that works.

Pitch and snow move the number by tens of per cent, not by factors. Going from 3:12 to 12:12 takes the default load from 0.28 to 0.18, and doubling the snow from 8 to 16 takes it from 0.24 to 0.33. Neither is a substitute for the ceiling work.

Frequently asked questions

Because the insulation is only half of the heat path. Air leaking out of the house carries heat past it entirely, and on a typical unsealed ceiling that path is several times larger than conduction through R-30. Sealing the ceiling is what removes it, and the difference between 0.10 and 0.04 in this calculator is bigger than the difference between R-30 and R-49.

Under 0.05 is low, 0.05 to 0.15 moderate, 0.15 to 0.30 high and above 0.30 very high, in inches of water per day at the eave. The thresholds are a screening convention rather than a code requirement: they separate roofs that rarely ice from roofs that ice in an ordinary winter.

No. It stops the water that backs up behind the dam from getting into the deck, which is the damage rather than the cause. The dam still forms, the icicles still hang, and the load on the eave is unchanged. It is a second line of defence, and the first is the ceiling.

Count what is cut into the ceiling. A sealed top plate with a gasketed hatch is around 0.04. A hatch, a few wiring holes and a bath fan take it to about 0.10. Recessed lights, a dropped soffit, an open chase or ductwork in the attic put it at 0.25 or beyond. A blower-door test with a ceiling-leakage reading is the only way to know rather than guess.

They open a channel so water can escape, and they run on electricity every hour they are on. They do not remove the heat source, so the dam keeps being fed and the cable keeps being needed. Treat them as a way to get through this winter while the ceiling is fixed, not as the fix.

Two reasons that pull the same way: snow slides off before it can build a reservoir, and meltwater runs to the eave faster than it can refreeze on the way. The calculator discounts the load as the pitch rises, but the effect is smaller than most people expect — 3:12 to 12:12 moves the default roof from 0.28 to 0.18.

Enter a winter design day, not today's weather. If the outdoor temperature is above the indoor one the meltwater goes to zero and the band reads low, which is correct but not useful. The figure is meant to describe the cold week that builds a dam, not the afternoon you happen to be reading it.

No. It compares heat paths, and the leakage figure is an estimate. Whether a particular ceiling is leaking, where the water is getting in and how much damage it has already done are questions for someone standing in the attic with a torch. The roof inspection calculation covers what that visit should include.

Where these numbers come from

The heat flow is the temperature difference across the ceiling multiplied by its conductance, which is the insulation term plus the air leakage term. Meltwater converts at 31.2 BTU/ft²/h per inch of water per day; snow and pitch apply dimensionless factors.

No R-value, leakage figure or snow depth is asserted here, because all three describe a particular building in a particular climate.

  • The mechanism and the priority. Building Science Corporation — BSI-046, Dam Ice Dam sets out the three conditions an ice dam needs and states plainly that air leakage matters more than insulation level, though both matter. It also notes that snow insulates at roughly R-1 per inch, which is why even a good roof can dam in a deep pack.
  • Why sealing comes first. ENERGY STAR — Attic Air Sealing Project is the practical sequence: seal the ceiling plane, then insulate over it, and it lists the penetrations that make up most of the leakage.
  • The leakage figures. Blower-door testing gives the real number. The 0.04, 0.10 and 0.25 bands are estimates for a sealed, typical and leaky ceiling, expressed per square foot of ceiling at a 1°F difference.
  • The snow and pitch factors. Dimensionless heuristics, not measurements. They are included because depth and slope both change the outcome, and the limitations section says so.